Subject to change.
Roto Safe C | C600 | C600 – Tandeo | H600
IMO_457_DE_v0
July 2017
45
Configuration and operation
Operation of daytime unlocking mechanism Roto Safe C | C600 Tandeo
Operation
Activating the day function
1.
Push the handle all the way down.
2.
Keep the handle pushed down. Turn the changeover
switch to the right (clockwise), into the horizontal
position.
The magnetic chip supplied is used as a changeover
tool.
For storage, affix the magnetic chip to the faceplate.
3.
Release the handle.
NOTE
Activate the electrical opener on the frame.
The additional locks remain retracted. The door can
now be pushed without using the handle and opened
without using a key. This requires the electrical opener
in the frame component to be set to day function (see
detail).
NOTE
The VDS certificate is no longer valid with
the day function activated.
Deactivating the day function
1.
Push the handle all the way down.
2.
Keep the handle pushed down. Turn the changeover
switch to the left (anticlockwise), into the vertical
position.
3.
Release the handle.
NOTE
Deactivate the electrical opener on the
frame.
The additional locks extend. The door can now only
be opened by pushing the handle or using a key.
(Set electrical opener in the frame component to
night function (see detail)).