Subject to change.
Roto Safe C | C600 | C600 – Tandeo | H600
IMO_457_DE_v0
July 2017
55
Maintenance
Roto Safe C performance test – Cylinder-operated multi-point locking systems
When the door is closed
REQUIREMENT
The door and door frame must be vertical for the performance test.
Check the locking process.
Close the door.
> The latch must run into the frame component and keep the door closed.
> Tandeo: the latch and all deadbolts must trigger automatically and freely move into the frame components.
Check opening by lever handle.
With the door closed, push the lever handle all the way down.
> The latch must retract fully so that the door can be opened.
> Tandeo: the latch and all deadbolts must retract so that the door can be opened.
Check locking by key.
With the door closed, turn the key in the locking direction.
> The key must be easy to turn.
> The latch and all deadbolts must run smoothly and extend fully.
Check unlocking by key.
With the door locked, turn the key in the unlocking direction.
> The key must be easy to turn.
> The latch and all deadbolts must retract fully.
Have malfunctions remedied by a specialist company.