Page 25
1355 - 1505 CYCLONE VERTICAL MIXER OPERATION
Input and output faults
Motor 1 pressure transducer is shown in fault status.
Page 3: Fault Page1
Display will revert to page 1 operation page after 5 seconds.
Motor 1 PSI and Motor 2 PSI: Pressure transducer faulted. Check connection at
transducer. Check sensor power and ground.
Motor 1 and Motor 2 PPU: With the pump output on and operating at a lower pressure
(less than 6000 psi) than a stalled condition; when there is no pulse feed back speed.
Motor high speed solenoid transducer is shown in fault status.
Page 4: Fault Page2
Display will revert to page 1 operation page after 5 seconds.
PTO PPU: When the motors are turning but the PTO PPU is not receiving this input. Can
be tested in Warm Up mode.
Pump PWM 1 and 2: Pump output is shorted or open.
Motor High Speed: Coil for the motor displacement shift to min is open or shorted.
J1939 CAN 2 communication is not connected for the keypad.
HOURS and TENTHS of PTO run time.
II. Limp Mode :
Shown with Loop 1 pressure in fault condition; open fault.
Push and hold the momentary Limp push button. After time delay, set at 5 seconds, the limp
operation will begin. Release button and limp stays on. Press again and limp will shut off.
Auger motors will operate in maximum displacement.
Pump output will be at the limp mode percent setting, set at 80%.
In a fault condition with a
3 blink code (See note in LED-Error Status)
the augers can be
operated in Limp Mode (limp mode can also be operated without a fault: