background image

 

Owners Manual 

 

 

 
Dealer:  

Liquid Leisure Hot Tubs

 

 
Dealer Address:  

Box 290, Woodlands, MB

 

 
Dealer Telephone:  (

204) 477-8827

 

 
Spa Model:  

RSO1

 

 
Serial No: _______________________________________________________________ 
 
Gallons / Liters:  

270 gal – 300 gal (1020 L – 1134 L)

 

 
Weight:  

275 lbs (125 Kilogram)

 

 
 
 
 
 
 
 
 
 

 

1565 County Road 18 

Lakefield, Ontario 

K0L 2H0 

Phone 705-652-1849 
Phone 877-768-6772 

Fax 705-652-7295 

 

info@rotospa.com

 

www.rotospa.com 

Summary of Contents for RSO1

Page 1: ... 477 8827 Spa Model RSO1 Serial No _______________________________________________________________ Gallons Liters 270 gal 300 gal 1020 L 1134 L Weight 275 lbs 125 Kilogram 1565 County Road 18 Lakefield Ontario K0L 2H0 Phone 705 652 1849 Phone 877 768 6772 Fax 705 652 7295 info rotospa com www rotospa com ...

Page 2: ...renity and satisfaction that your Roto Spa will bring The information and instructions set out in this Owner s Manual are provided to help you to use your Roto Spa and care for it as easily as possible We ask you to read the manual thoroughly Your Roto Spa dealer will be happy to assist if you have any questions Your comments and suggestions are always appreciated We welcome all correspondence and...

Page 3: ...r flow created by the pump Should the need arise to replace the suction fittings or the pump be sure that the flow rates are compatible Never operate the spa if the suction fittings are broken or missing Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting 5 DANGER Risk of Electric Shock Install at least 5 feet 1 5m from all metal surfaces A...

Page 4: ... following 1 READ AND FOLLOW ALL INSTRUCTIONS 2 A green coloured terminal or a terminal marked G GR Ground Grounding or the symbol is located inside the supply terminal box or compartment To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors...

Page 5: ...T ET SORTANT DE LA CUVE DE RELAXATION Warning Do not use drugs or alcohol before or during the use of a Roto Spa hot tub to avoid unconsciousness and possible drowning AVERTISSEMENT POUR EVITER L EVANOUISSEMENT ET LA NOYADE EVENTUELLE NE PRENDRE NI DROGUE NE ALCOOL AVANT D UTILISER LA CUVE DE RELAXATION NI QUAND ON S Y TROUVE Warning Pregnant or possible pregnant women should consult a physician b...

Page 6: ...cription of the causes symptoms and effects of hyperthermia are as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37 C 98 6 F The symptoms of hyperthermia include drowsiness lethargy and an increase in the internal temperature of the body The effects of hyperthermia include Unawareness of impending hazard F...

Page 7: ...anty Never use an extension cord to connect the Roto Spa to the power source Using an extension cord will void your warranty Do not operate without an approved ground fault circuit interrupter This safety device shuts off the power immediately in the event of an electrical short Install the Roto spa only on floors or areas that can withstand repeated exposure to water Splashing dripping filling an...

Page 8: ... on grass or dirt to enter the Roto Spa we recommend the use of stepping stones to reduce the amount of dirt and debris entering the tub ANY DAMAGE CAUSED BY THE SPA RESTING ON AN UNEVEN SURFACE WILL NOT BE COVERED BY THE WARRANTY When considering an installation site always allow for easy access to your equipment The installation site should also allow enough room to completely remove and store t...

Page 9: ...n Your Roto Spa comes ready to install using an 110V 15amp corded connection complete with an inline GFCI ready to plug into a dedicated 15amp household circuit Roto Spas have been designed to meet the maximum safety requirements to prevent electrical shock Improper wiring may cause electrocution risk of fire risk of injuries and damage to the equipment Never use an extension cord to connect the R...

Page 10: ...to 8 cm over the skimmer filter opening Low water levels can cause damage to the pump and heater unit Check all connections for leaks and hand tighten union fittings as required The equipment may shift slightly during transportation 6 Reinstall the skimmer basket and filter lid once the spa is filled and check to ensure that the filter is installed correctly 7 After the spa has been filled with wa...

Page 11: ...p when a filter cycle is on Winterizing 1 Remove the filter cover 2 Remove the filter basket and filter 3 Use a siphon hose garden hose to drain the Roto Spa completely To start the siphon you can put the siphon hose over a jet while the pump is running on high speed until the hose is completely full and then put the hose at the bottom of the foot well Turn off the power to the Roto Spa and let th...

Reviews: