10. Fault memory
The fault memory stores the last 14 system faults. These faults can be
called up by corresponding DIP switch settings.
Apart from this, the number of faults can be examined or all faults cleared.
DIP switch
Description
Feedback signal
Personal setting
1 1 1 0
0 0
0 0
Feedback = Number of stored faults
matches number of signals
0 1
1. Display fault memory
1 0
2. Display fault memory
1 1
3. Display fault memory
0 1
0 0
4. Display fault memory
0 1
5. Display fault memory
1 0
6. Display fault memory
1 1
7. Display fault memory
1 0
0 0
8. Display fault memory
0 1
9. Display fault memory
1 0
10. Display fault memory
1 1
11. Display fault memory
1 1
0 0
12. Display fault memory
0 1
13. Display fault memory
1 0
14. Display fault memory
1 1 Acknowledge / delete all faults
Fault codes for faults at position 1-14
(Number of tones issued)
Fault
1
RAM fault
2
ROM fault
3
Hall fault
4
Undervoltage fault
5
Excess current fault
10
Fault memory overrun
11. Special functions
Teach-in of zero position, usually this is the closed door position.
Teach-in of maximum opening angle for the door, the angle which
describes how far the door swings open when electrically opened. These
two settings must undergo teach-in before being used for the first time!
Similarly, the configurations have to be reset to factory settings.
DIP switch
Description
Feedback signal
Personal setting
1 1 1 1
0 0 0 1 Programming the zero position
0 0 1 0 Programming the maximum opening angle
1 1 1 0 Resetting to factory settings*
Optional settings