8.2.4 Deleting hand-held transmitters
INFO
It is not possible to delete individual hand-held transmitters.
1. Unlock and open the door.
2. With the door open, lock the lock using the key.
3. Press and hold the radio calibration push-button for at least 10 seconds.
Once Eneo C | CC | CF has detected the signal from the radio calibration push-button, it will confirm this with two
beeps heard in quick succession.
All calibrated hand-held transmitters are deleted.
Eneo C | CC | CF exits calibration mode automatically.
8.2.5 Changing the battery
1. Undo three screws on the back.
2. Open the housing.
3. Insert a new battery. Ensure that the polarity is correct.
ATTENTION
Incorrect disposal may pollute the environment.
Leaking battery acid may pollute the environment.
u
Do not dispose of the battery in household waste.
u
Observe the national regulations on the disposal of batteries.
4. Fit the housing and secure with three screws.
8.2.6 Fault assistance
Fault
Cause
Fault rectification
The hand-held transmitter LED flickers or does not light up
when a button is pressed.
Battery too weak or flat.
Replace the batteries of the hand-held trans-
mitter.
The motorised lock is not working when a button on the hand-
held transmitter is pressed.
Hand-held transmitter not
calibrated or fault during
calibration.
Repeat the calibration process for the hand-held
transmitter on the motorised lock.
Commissioning and operation
Hand-held transmitter
Deleting hand-held transmitters
Subject to change.
Roto Safe E Eneo C | CC | CF
IMO_438_EN_v3
·
05 / 2020
· 73