background image

Roto Safe

 

Eneo

Note

Incorrect installation, maintenance or
operation can lead to hazardous situations.

This extract is not a replacement for complete
documentation. Failure to observe this
documentation discharges the hardware
manufacturer from their liability.

u

Note the complete installation, mainte-
nance and operating instructions (IMO).

The complete documentation for this extract is as
follows:

Roto Safe Eneo installation instructions:
C | CC | CF: IMO_438
Control Unit: IMO_288

Roto Safe Eneo brief instructions:
Power supply unit specifications (third-party
product): SUG_3
General information: SUG_9, SUG_10

Connection diagrams
Roto Safe Eneo: IMO_310

DANGER

Risk of death caused by electric
shock

Current can lead to fatal injuries.

u

Installation and maintenance work may
only be carried out by qualified electri-
cians.

u

Observe and comply with the respective
national regulations (in Germany VDE
0100 and others).

u

When laying the network connection
cable on-site, all-pole safety isolation
must be established.

u

Only carry out work when the power
supply is disconnected.

Technical data

Roto Safe Eneo drive

Voltage

24 V DC (±5%), 2.5 A, SELV output voltage
according to EN 60950-1

Continuous current
consumption

25 mA

Current consumption

1.5 A (peak 2.3 A)

Relative air humidity

≤ 93%

Temperature

–25 to +60 °C (transport –25 to +70 °C)

Output relay load

Max. 40 mA, flyback diode for inductive load
present internally

Standards

EN 60 730-1,

EN 50090-2-2

Low Voltage Directive complied with,

CE conformity

Cable junction

 (on the sash side)

Max. voltage

48 V DC

Max. current

3 A

Line

LiF9Y11Y, six-pole version,
Ø 4.9 mm, grey

Line length on the connector
side

4 m

Degree of protection in
accordance with DIN 40050

IP67 (when inserted)

Temperature when idle

–40 to +75 °C

(transport –5 to +50 °C)

Cores

0.34 mm

2

 (white, green, brown,

yellow, pink, grey)

Power supply unit

DC voltage

24 V (output)

Rated current

2.5 A (output)

Voltage adjustment range

21.6 to 26.4 A (output)

Voltage range

88 to 264 V AC, 124 to 370 V DC (input)

Frequency range

47 to 63 Hz (input)

Temperature

–20 to +60 °C

Relative air humidity

20% to 93%

INFO

If a different power supply unit is used,
ensure that it has 24 V and 2.5 A at the
output (see SUG_3).

Roto Safe Eneo

Subject to change.

Roto Safe Eneo

SUG_11_EN_v0

 · 

04 / 2019

 · 1

Summary of Contents for Safe Eneo Series

Page 1: ... out work when the power supply is disconnected Technical data Roto Safe Eneo drive Voltage 24 V DC 5 2 5 A SELV output voltage according to EN 60950 1 Continuous current consumption 25 mA Current consumption 1 5 A peak 2 3 A Relative air humidity 93 Temperature 25 to 60 C transport 25 to 70 C Output relay load Max 40 mA flyback diode for inductive load present internally Standards EN 60 730 1 EN ...

Page 2: ...not connected not connected green green green yellow white white white white EZ cable 3m insertable cable junction on the sash on the frame power supply Eneo Switch IN 100 240V AC OUT 24V DC 2 5A plug cable assignment white IN1 Input 1 open brown 24V green GND yellow not connected grey not connected pink not connected Roto Safe Eneo 2 04 2019 SUG_11_EN_v0 Roto Safe Eneo Subject to change ...

Page 3: ...ight operation mode This can be used as an option Terminals 5 and 6 are connected to one another internally via a relay and a 47 ohm resistor The maximum load of the contacts is 24 V 40 mA Maximum line lengths Eneo cable junction insertable 180 incl 4 m cable with round connector for Eneo Control Unit up to power supply unit From Eneo cable junction connector Up to 4 m Up to 10 m Up to 20 m Up to ...

Page 4: ...pproximately 2 seconds Unlocking the door from the outside Depending on the access control system available unlocking can be triggered by hand held transmitter finger scan Phone Code etc INFO If the deadbolt is locked the lock cannot be opened electronically Unlocking the door from the inside The Eneo C multipoint locking system can only be unlocked using a key or electrical signal e g push button...

Page 5: ...ing the Eneo Control Unit Contact qualified personnel Roto Safe Eneo does not lock automati cally Door is not fully closed Close the door fully Multipoint locking system is in day operation mode Change over to night operation mode input 2 must not be set to 24 V for night operation mode Rebate magnet is adjusted incorrectly Check the position of the magnet and adjust if necessary Adjust the door a...

Page 6: ...ioned adjusted correctly Lock the door again Position the magnet correctly and lock the door again 3x two tone beeps Fault Control unit detected excess current in the motor and stopped Remove blocks If the door is not running smoothly contact the door manufacturer 4x two tone beeps Fault The final position of the connecting rod was not reached in the maximum permitted time of 3 seconds No movement...

Page 7: ...Str 21 A 8401 Kalsdorf bei Graz Austria Notausgangsverschluss lt EN179 E611 LE DoP Nr KD Door E611 Nr 001 CPR 2016 05 17 16 EN 179 2008 04 Notausgangsverschluss mit Drückerbetätigung Typ A für Türen in Rettungswegen für außen und innen öffnende Türen n e d n a t s e b e b a g i e r F r u z t i e k g i h ä F 1sec W 100mm A 70N Dauerfunktionstüchtigkeit hinsichtlich der Fähigkeit zur Freigabe gegenü...