Acoustic signals

Sound

Message

Meaning

Corrective action

1x beep

Confirmation Command understood, process completed correctly.

-

3x short beeps

Note

Command understood but cannot be executed because the
maximum number of cycles in the time unit has been
exceeded.

Multipoint locking system was actuated too often in
a short time period. Let the motor cool down for
around 2 minutes to prevent damage.

4x short beeps

Note

Calibration push-button was actuated but calibration /
clearance is not possible.

Move the lock of the Eneo C multipoint locking
system to the correct position and recalibrate.

2x two-tone
beeps

Fault

The magnetic contact was interrupted during the locking
process. Either the door was opened again during this period
or the magnet was not positioned / adjusted correctly.

Lock the door again.

Position the magnet correctly and lock the door
again.

3x two-tone
beeps

Fault

Control unit detected excess current in the motor and
stopped.

Remove blocks.

If the door is not running smoothly, contact the
door manufacturer.

4x two-tone
beeps

Fault

The final position of the connecting rod was not reached in
the maximum permitted time of 3 seconds.

No movement noises are audible and no movement
of the lock is visible, motor faulty. Replace the lock.

5x two-tone
beeps

Note

Command from hand-held transmitter is executed but the
hand-held transmitter battery will soon be flat.

Replace the battery

7x two-tone
beeps

Note

Only for Eneo A multipoint locking system.

Calibration current values have either failed to reach or have
exceeded the specified values.

Recalibration required.

Have electrical installation work carried out by
qualified personnel.

Roto Safe Eneo

6 · 

04 / 2019

 · 

SUG_11_EN_v0

Roto Safe Eneo

Subject to change.

Summary of Contents for Safe Eneo Series

Page 1: ... out work when the power supply is disconnected Technical data Roto Safe Eneo drive Voltage 24 V DC 5 2 5 A SELV output voltage according to EN 60950 1 Continuous current consumption 25 mA Current consumption 1 5 A peak 2 3 A Relative air humidity 93 Temperature 25 to 60 C transport 25 to 70 C Output relay load Max 40 mA flyback diode for inductive load present internally Standards EN 60 730 1 EN ...

Page 2: ...not connected not connected green green green yellow white white white white EZ cable 3m insertable cable junction on the sash on the frame power supply Eneo Switch IN 100 240V AC OUT 24V DC 2 5A plug cable assignment white IN1 Input 1 open brown 24V green GND yellow not connected grey not connected pink not connected Roto Safe Eneo 2 04 2019 SUG_11_EN_v0 Roto Safe Eneo Subject to change ...

Page 3: ...ight operation mode This can be used as an option Terminals 5 and 6 are connected to one another internally via a relay and a 47 ohm resistor The maximum load of the contacts is 24 V 40 mA Maximum line lengths Eneo cable junction insertable 180 incl 4 m cable with round connector for Eneo Control Unit up to power supply unit From Eneo cable junction connector Up to 4 m Up to 10 m Up to 20 m Up to ...

Page 4: ...pproximately 2 seconds Unlocking the door from the outside Depending on the access control system available unlocking can be triggered by hand held transmitter finger scan Phone Code etc INFO If the deadbolt is locked the lock cannot be opened electronically Unlocking the door from the inside The Eneo C multipoint locking system can only be unlocked using a key or electrical signal e g push button...

Page 5: ...ing the Eneo Control Unit Contact qualified personnel Roto Safe Eneo does not lock automati cally Door is not fully closed Close the door fully Multipoint locking system is in day operation mode Change over to night operation mode input 2 must not be set to 24 V for night operation mode Rebate magnet is adjusted incorrectly Check the position of the magnet and adjust if necessary Adjust the door a...

Page 6: ...ioned adjusted correctly Lock the door again Position the magnet correctly and lock the door again 3x two tone beeps Fault Control unit detected excess current in the motor and stopped Remove blocks If the door is not running smoothly contact the door manufacturer 4x two tone beeps Fault The final position of the connecting rod was not reached in the maximum permitted time of 3 seconds No movement...

Page 7: ...Str 21 A 8401 Kalsdorf bei Graz Austria Notausgangsverschluss lt EN179 E611 LE DoP Nr KD Door E611 Nr 001 CPR 2016 05 17 16 EN 179 2008 04 Notausgangsverschluss mit Drückerbetätigung Typ A für Türen in Rettungswegen für außen und innen öffnende Türen n e d n a t s e b e b a g i e r F r u z t i e k g i h ä F 1sec W 100mm A 70N Dauerfunktionstüchtigkeit hinsichtlich der Fähigkeit zur Freigabe gegenü...

Reviews: