5 Connection diagram
The following diagrams are non-binding application examples.
These are only intended to provide guidance for customers and do not represent customer-specific solutions.
Proper operation is the responsibility of the customer.
The customer is obligated to ensure safe installation, use, maintenance and operation. The customer is furthermore
obligated to ensure that the equipment is only installed by a qualified electrician; failure to do so may result in a risk of
fire or risk of electric shock.
Compliance with the applicable standards and provisions must be ensured at all times; the installation company of
the system bears full responsibility for this.
The system may not be operated if compliance with the applicable standards and provisions cannot be ensured.
No guarantee is given for the application examples provided. Roto Frank Fenster- und Türtechnologie GmbH shall
assume no liability for damage caused by use of the application examples, unless we are obligated to bear liability in
accordance with legal provisions in cases of wilful intent.
Other connection diagrams: IMO_310
INFO
Installation and maintenance work may only be carried out by a company specialising in electrical
systems. There is a risk of death when using a mains voltage of 230 V (or 115 V). Only carry out work
when the power supply is disconnected.
INFO
For a cable junction with built-in power supply unit, external components are clamped directly on to the
cable junction on the frame. The cable junction must be removed so that you can do this.
To connect external components, connect a 6 x 0.34 mm
2
cable to the cable junction and route it outwards.
Terminal assignment of cable junction with built-in power supply unit:
Terminal 1 IN1 / input 1 (OPEN)
Terminal 2 +24 V
Terminal 3 GND
Terminal 4 IN2 / input 2
Terminal 5 K1a pot.-free contact
Terminal 6 K1b pot.-free contact
INFO
Terminals 5 and 6 are connected to one another internally via a relay and a 47 ohm resistor. The maximum
load of the contacts is 24 V / 40 mA.
The following basic circuits are used as examples.
Connection diagram
32 ·
05 / 2020
·
IMO_502_EN_v2
Roto Safe - Cable junctions
Subject to change.