7.1 Maintenance intervals
ATTENTION
Failure to adhere to maintenance intervals may cause property damage.
The maintenance interval for all tasks relating to the hardware components is
annually
at the least. In
hospitals, schools and hotels, the maintenance interval is
six-monthly
.
Regular maintenance is necessary in order to maintain the proper and smooth-running operation of the
hardware and to prevent premature wear or even defects.
u
Determine and adhere to the appropriate maintenance interval in accordance with the ambient condi-
tions.
7.2 Cleaning
ATTENTION
Using incorrect cleaning agents and sealing compounds may cause property damage.
Cleaning agents and sealing compounds may damage the surfaces of components and gaskets.
u
Do not use aggressive or flammable liquids, acidic cleaners or abrasive cleaners.
u
Only use mild, pH-neutral cleaning agents that have been diluted.
u
Apply a thin protective film to the components, for example using a cloth soaked in oil.
u
Avoid aggressive vapours (e.g. produced by formic acid, acetic acid, ammonia, amine compounds,
ammonia compounds, aldehyde, carbolic acid, chlorine, tannic acid) around the element.
u
Do not use any acetic acid-crosslinking or acid-crosslinking sealing compounds or those with the
aforementioned constituents as both direct contact with the sealing compound and its fumes can
corrode the surface of the components.
Cleaning the hardware
u
Clean deposits and contaminants off the hardware using a soft cloth.
u
Lubricate movable parts and locking points after cleaning.
u
Apply a thin protective film to the hardware, for example using a cloth soaked in oil.
7.3 Performance test
PRECONDITION
The sash and frame must be vertical for the performance test.
When the door is open
Fixing screws
ATTENTION
Over-tightened screws may cause property damage.
Over-tightened screws lose their hold and no longer provide the necessary strength.
u
Do not over-tighten screws. Note the torque.
Use a screwdriver to check that all fixing screws have been tightened.
Door lever handle function
Push the door lever handle all the way down and release.
u
The door lever handle must automatically return to the initial position.
Maintenance
Maintenance intervals
Subject to change.
Roto Safe - Cable junctions
IMO_502_EN_v2
·
05 / 2020
· 37