8. SAFETY FEATURES AND PROTECTION
The safety control prevents the motor from being switched on when the mixing bowl is not
in position, and stops it if the bowl is raised during operation.
When the bowl is replaced, the speed control knob must be turned back to “0”
(reset function), before the motor can be restarted.
Only the speed control knob can be used to turn the
machine on and off.
When the machine is overloaded or overheated, it switches off
automatically.
If this occurs, after about 60 seconds, please press the black button
on the bottom plate of the motor base.
If you notice any irregularities or defects, please contact your
supplier. For more information see chapter “Repairs”.
9. CLEANING
If necessary, clean the motor unit with a damp cloth.
Container:
The mixing container should not be cleaned in the dishwasher while still
installed (see chapter «Operating instructions»;
left-threaded!
). They must
first be dismantled.
The container should be cleaned thoroughly after each use or once a day.
Bowl:
clean by hand using hot water and a commercial cleaning product, they can also
be cleaned in the dishwasher.
Cutter asm.:
simply rinse and, if necessary, scrub off.
Never place into
water or the dishwasher
.
Threaded ring:
should be cleaned especially inside, by using a hard brush.
The motor unit must never be submerged in, or sprayed with water or any other
liquid! Never attempt to clean it with a water jet!
10. MAINTENANCE
The motor bearings are permanently lubricated and therefore require no maintenance.