Keeping the World Flowing
51
12.0 Maintenance
Routine maintenance should include the following:
• Check actuator to valve fixings bolts for tightness
• Ensure valve stems and drive shafts are clean and
properly lubricated
• If the motorized valve is rarely operated, a schedule of
operation should be set up and adhered too
• Check the actuator for damage, loose or missing fixings
• Ensure that there is not an excessive build up of dust or
contaminate on the actuator
13.0 Disposal / Recycling
User advice on disposal of your product at the end of its life.
Please refer to table below. In all cases check local authority
regulations before disposal.
Subject
Definition
Remarks / examples
Hazardous Recycleable
EU Waste
Code
Disposal
Electrical &
Electronic
Equipment
Printed circuit boards All products
Yes
Yes
16 02 14
Use specialist recyclers
Wire
All Products
No
Yes
16 02 16
Glass
Lens/Window
CMA
No
Yes
20 01 02
Metals
Aluminium
Brackets/housings
No
Yes
20 01 40
Use specialist
metal recyclers
Copper/Brass
Wire, motor windings/PCBAs
No
Yes
20 01 40
Zinc
N/A
No
Yes
20 01 40
Iron/Steel
Gears and shafts
No
Yes
20 01 40
Mixed Metals
Bushings
No
Yes
20 01 40
Plastics
Glass-filled nylon
Electronic chassis
No
Yes
07 02 13
Disposal as general
commercial waste
Unfilled
Gears and bearings
No
Yes
07 02 13
Window Sealant Silicone
Window adhesive
Yes
No
08 04 09
Will require special
treatment before disposal.
Use specialist recyclers or
waste disposal companies
Adhesive
Anaerobic Sealant
Thread locker
Yes
No
08 04 09
Grease
Grease
Gears and ball screws
Yes
No
13 02 08
Rubber
Seals & O-rings
Cover and shaft sealing
No
No
07 02 99
May require special
treatment before disposal.
Use specialist waste disposal
companies
Fig 13.6 CMA Disposal recycle chart
A4
US
US
A4
US
A4
A4
US