8
Installation & Maintenance
Instructions
3.0 Approvals
3.4 Special Conditions For Safe Use (FMC, ATEX & IECEx approved actuators)
In accordance with clause 5.1 of IEC/EN 60079-1, the critical dimensions of the flamepaths are:
CML-1500/3000
Flamepath
Maximum Gap (mm)
Maximum Width L (mm)
Lid/base
0.20
26.4
Screw shaft bushing / shaft
0.10
68.5
Base / screw shaft bushing
0.361
36.96
Handwheel shaft / base
0.20
27.9
3.3 Environmental Conditions
a) Altitude up to 5000 meters
b CMA adheres to requirements consistent with Overvoltage Category II
c) The CMA adheres to the requirements consistent with a Pollution Degree of 2
3.5 Certification Numbers
Canada (FMC)
FM18CA0156X
Europe (ATEX)
FM17ATEX0012X
International (IEC) IECEx FMG 17.0007X
3.6 Safety Warnings
WARNING
The screws securing the outer window frame maintain
the integrity of the flame proof enclosure and must
NOT be removed.
WARNING
The equipment utilizes a non-metallic outer coating
and has a potential static hazard. Clean only with a
damp cloth.
A4
US
US
A4
US
A4
US
A4