73
Refer to actuator nameplate for
unit specific approval details.
Rotork Fluid Systems actuators are
approved to many standards. Refer
to www.rotork.com for the latest
information.
Rotork can supply actuators to national
standards not listed below. For details
please contact Rotork.
European
EH 1.1 Pro:
ATEX (94/9/EC) II 2 G. EEx d(e) IIB T4 Gb
Temperature: -20°C to +60°C
*Option: -40°C to +60°C
*Option: -50°C to +60°C
International
EH 1.1 Pro:
IECEx. Ex d(e) IIB T4 Gb
Temperature: -20°C to +60°C
*Option: -40°C to +60°C
*Option: -50°C to +60°C
Canada
EH 1.1 Pro:
Rotork Supplies CSA approved Motor,
Cable, Cable Glands and Accessories.
Local certification to CSA standards
required.
USA
EH 1.1 Pro:
FM. Class I, Division 1, Gas Groups C &
D (XP/I/1/CD)
FM. Class II, Division 2, Gas Group E, F &
G (DIP/II/1/EFG)
Enclosure: NEMA Type 6
Temperature Code: T4
Temperature: -40°C to +60°C
*Option: -50°C to +60°C
* “e” increased safety terminal facility
is only available on single-phase and DC
versions when specified.
Note: Certification temperatures are
not operating temperatures, see
actuator nameplate for operating
temperatures.
14
Hazardous Area Approvals
Approved Fuses
14.1
See wiring diagram as stated on
the data label for approved fuse
details.
The table below shows fuse
specification reference.
Input Power Voltages
Bussman Order Code
3-Phase 50 Hz
190, 200, 220, 240 VAC
TDC11-250mA
3-Phase 50 Hz
380, 400, 415, 440, 480, 500,
525, 550, 660, 690 VAC
TDC11-150mA
3-Phase 60 Hz
200, 208, 220, 230, 240 VAC
TDC11-250mA
3-Phase 60 Hz
380, 400, 440, 460, 480, 575,
600, 660, 690 VAC
TDC11-150mA
1-Phase 50 Hz
110, 115 VAC
TDC11-500mA
1-Phase 50 Hz
220, 230, 240 VAC
TDC11-250mA
1-Phase 60 Hz
110, 115 VAC
TDC11-500mA
1-Phase 60 Hz
208, 220, 230, 240 VAC
TDC11-250mA
24 VDC
TDC11-5A