30
IQT3 manual – Section: Approved Fuses
13. Approved Fuses
AC – FS1
Transformer
Value
Manufacturer
Part number
Type 1
5.0A Anti-Surge
Schurter
8020.5018
SIBA
70-065-65
Type 2
2.5A Anti-Surge
Schurter
8020.5015
SIBA
70-065-65
Type 3
2.0A Anti-Surge
Schurter
8020.5014
SIBA
70-065-65
Type 4
2.0A Anti-Surge
Schurter
8020.5014
SIBA
70-065-65
AC – FS2
Transformer
Value
Manufacturer
Part number
Types 1-4
20A ATO
Littlefuse
166.7000.5206
DC – FS1
Transformer
Value
Manufacturer
Part number
Types 5
20A ATO
Littlefuse
166.7000.5206
DC – FS2
Transformer
Value
Manufacturer
Part number
Types 5
500 mA
Bussmann
S505-500-R
FS3 – (Battery loom on ATEX builds only)
Transformer
Value
Manufacturer
Part number
All
100 mA Quick blow
Bussmann
S500
Littlefuse
217
14. Vibration, Shock and Noise
Standard IQT range actuators are suitable for applications where vibration and
shock severity does not exceed the following:
Type
Level
Plant induced vibration
1g rms total for all vibration within the frequency range of 10 to 1000 Hz
Shock
5g peak acceleration
Seismic
2g acceleration over a frequency range of 1 to 50 Hz if it is to operate
during and after the event
Emitted noise
Tests have shown that at 1m generated noise does not exceed 65 db(A)