Keeping the World Flowing
31
PM-LP-006a
Page: 1/10
Component:
Single-acting actuator
Task:
LP type 0 pneumatic cylinder seals replacement
Equipment, Tools, Materials:
Spare seals
Wrench
Lifting clump
Lifting tools
Project documentation
Warnings:
Description:
Note: the following instructions apply to single-acting actuator unless otherwise specified.
Cut-off power supply and electric power supply (if present) before performing any operation.
Adequate lifting devices and suitable for the weight must be applied by skilled personnel.
Preliminary actions
1. Remove actuator from valve and remove all couplings as well (see Removal from Valve, page 11)
2. Position the actuator on a workbench (if possible) or in a stable position and in a clean and closed area
3. Remove any control equipment (if present). Refer to the project specific documentation
4. Remove pneumatic pipes
APPLICABLE TO TYPE 0 WITH STOP BOLT ONLY (5)
5. Measure length (W)
W
6. Hold stop bolt (3) with a wrench and loosen and remove
stop nut (1)
3
16.0 Periodic Maintenance
A4
US
US
A4
US
A4
A4
US
Summary of Contents for LP/S Series
Page 89: ...Keeping the World Flowing 89...