Activation CY-drives
min.
typ.
max.
unit
Performance data Y and U
• Activation Y
U
(for 10
k
Ω
)
• Feedback U
U
(for 2000
k
Ω
…
∞ Ω
)
0
0
10
10
VDC
VDC
Environmental conditions
min.
typ.
max.
unit
Humidity (not condensing)
90
% rH
Protection class as per DIN EN 60529
IP66
Operation
• Ambient temperature (T6)
• Ambient temperature (T5)
–40
–40
+40
+50
°C
°C
Storage
• Ambient temperature
–40
+70
°C
*: Nominal value: please note that nominal values are also subject to tolerances. For more
detailed information, see:
3.10.21 Max-15.30, Max-15.30-CTS, Max-15.30-VAS
Mechanical characteristics
min.
typ.
max.
unit
Motor torque (can be configured with rotary switch)*
15 / 30
Nm
Motor run time for 90° (can be configured with rotary switch)*
3
15
30
60
120
s
Minimum angle of rotation*
-5
°
Maximum angle of rotation*
90
°
Weight*
• Max-15.30
• Max-15.30-CTS
• Max-15.30-VAS
3.5
3.5
5.3
kg
kg
kg
Dimensions
min.
typ.
max.
unit
Max-15.30
L
W
H
–1
–1
–1
210
96
80
+1
+1
+1
mm
mm
mm
3 | Device description
Translation of the original installation guide · Version 1.0 · 2021-05-27