Electrical characteristics limit switch
min.
typ.
max.
unit
After one-off operation
with U > 24
VAC/DC or I > 100
mA:
• U
min
AC/DC*
• I
min
AC/DC*
12
100
V
mA
Environmental conditions
min.
typ.
max.
unit
Humidity (not condensing)
90
% rH
Protection class as per DIN EN 60529
IP67
Operation
• Ambient temperature (T6)
• Ambient temperature (T5)
–40
–40
+40
+50
°C
°C
Storage
• Ambient temperature
-40
+70
°C
*: Nominal value: please note that nominal values are also subject to tolerances. For more
detailed information, see:
3.10.34 Max-30-SF3, Max-30-SF3-CTM, Max-30-SF3-VAM
Mechanical characteristics
min.
typ.
max.
unit
Motor torque*
30
Nm
Motor run time for 90° (can be configured with rotary switch)*
40
60
90
120
150
s
Spring torque*
30
Nm
Spring return period for 90°
(at temperatures below -20
°C, depending on the load, the
spring return period can be up to 20
s)*
~3
s
Load torque, value must not be below this
8
Nm
Minimum angle of rotation*
-5
°
Maximum angle of rotation*
90
°
Weight*
• Max-30-SF3
• Max-30-SF3-CTM
• Max-30-SF3-VAM
9.5
9.5
17.4
kg
kg
kg
3 | Device description
Translation of the original installation guide · Version 1.0 · 2021-05-27
137