SI manual – Section: SI Approvals
37
14. SI Approvals
Refer to actuator nameplate for unit
specific approval details.
Depending on the full equipment
configuration, the following European
Directives may be applicable:
- ATEX Directive 2014/34/EU
- Pressure Equipment Directive
2014/68/EU
- Machinery Directive 2006/42/EC
SI3 and SI4 Electrohydraulic Control
Modules have the following approvals:
European – Hazardous Area
ATEX 2014/34 EU
(EN 60079-0, EN 60079-1, EN 60079-7,
EN ISO 80079-36, EN ISO 80079-37)
II 2G
Ex db
①
h IIB T4 Gb
Ex db
①
h IIC T4 Gb
T ambient =
②
to
③
International – Hazardous Area
IECEx
(IEC60079-0, IEC 60079-1 &
IEC 60079-7)
Ex db
①
IIB T4 Gb
Ex db
①
IIC T4 Gb
T ambient =
②
to
③
①
“e” added on versions with increased
safety terminal enclosure
SI3 and SI4 Actuators without
Accumulator
②
Down to -50 °C (-58 °F)
(Group – IIB & IIC)
③
Up to +70 °C (+158 °F)
(Group – IIB & IIC)
SI4 Actuators with Accumulator
②
Down to -50 °C (-58 °F) (Group – IIB)
③
Up to +70 °C (+158 °F) (Group – IIB)
②
Down to -20 °C (-4 °F) (Group – IIC)
③
Up to +70 °C (+158 °F) (Group – IIC)
Summary of Contents for Skilmatic SI 3