o

 

Vapor partial pressure (E) 

o

 

Vapor saturation pressure (Ew) 

 
Note: some of the above parameters depend on the value of the barometric pressure.  Using the ROTRONIC 
HW4 software, a fixed barometric pressure value can be specified. For instructions see the following HW4 
manual: 

E-M-HW4v2-F2-006

 

 

2.4    Service connector 

The service connector is a UART digital interface (Universal Asynchronous Receiver Transmitter) with a mini-
USB type connector. This allows connecting the HP22 either to a PC running the ROTRONIC HW4 software 
or to a probe input of another instrument that is compatible with the HygroClip 2 (HC2) probes. In both cases a 
service cable is required. 

See “Maintenance” for the location of the service connector and for the type of 

service cable to be used.  
 

  Connecting the HP22 to a PC is used to configure the HP22, gain access to the HP22 and probe functions 

such as humidity and temperature adjustment, read data from the HP22 on the PC and update the 
firmware of either the HP22 or probe. 

 

  Connecting the HP22 to another instrument is useful only when the other instrument has its own display 

and keypad, and has a more powerful internal menu than the HP22 (example HP23 hand-held calibrator). 
This allows showing the data measured by the HP22 on the other instrument display and also allows using 
the other instrument internal menu to do for example a humidity and temperature adjustment of the HP22. 

3  

User configurable settings and functions 

 
The HP22 can be used just as any conventional humidity and temperature indicator and most users will never 
need to use the HP22 configurable settings and functions. 
  
Making use of the HP22 configurable settings and functions is entirely up to the user and the appropriate 
settings depend on the user application. We have provided below a short description of the HP22 functions 
and also indicated the factory default settings. 
 

3.1    Function overview 

 

MEASUREMENT ACCURACY AND RELIABILITY (PROBE FUNCTIONS) 

AirChip 3000 Functions 

Description 

► Humidity / temperature adjustment 

o

  1-point or multi-point humidity calibration or adjustment 

o

  1-point or 2-point temperature calibration or adjustment 

o

  Generate a time stamp for calibrations and adjustments 

o

  Retain and view last adjustment date and adjustment values 

o

  Generate calibration and adjustment protocols 

► Automatic humidity sensor test 
     and optional drift compensation 

Tests the humidity sensor for drift caused by contaminants and 
can be used to automatically apply a correction. The test is 
automatically carried out at regular intervals of time. Can be 
configured, enabled, or disabled 
 
The humidity sensor status can be verified either with the HW4 
software or with the instrument display and is shown as Good, 
SQ-tuned (corrected for drift) or Bad (defective) 

Summary of Contents for HygroPalm HP22

Page 1: ...sersdorf Switzerland Document code Unit HygroPalm HP22 hand held indicator User Guide Instruction Manual Document Type Page 1 of 16 Document title 2009 2010 Rotronic AG E M HP22 V1_21 HygroPalm HP22 H...

Page 2: ...ings 5 3 3 Interaction between the HP22 and probe functions 7 4 Operation 8 4 1 Display 8 4 2 Keypad 8 4 3 Internal menu 9 4 4 Changing the parameters shown on the display 10 4 5 Changing the unit sys...

Page 3: ...nd 100 to 200 C 148 to 392 F The temperature operating range of the HP22 electronics is limited to 10 60 C Based on the ROTRONIC AirChip 3000 digital technology the HP22 indicator and HygroClip 2 prob...

Page 4: ...23 hand held calibrator This allows showing the data measured by the HP22 on the other instrument display and also allows using the other instrument internal menu to do for example a humidity and temp...

Page 5: ...d data can be downloaded to a PC with the HW4 software time stamped and viewed MEASUREMENT LOOP VALIDATION Functions Description Simulator mode Used to make the HP22 generate fixed values for the humi...

Page 6: ...djustment K Device write protection Disabled HP22 and probe Menu access from keypad Enabled Limit humidity output to 100 RH Enabled probe Out of limit value digital display alarm Disabled HP22 and pro...

Page 7: ...e name of the HC2 probe is not displayed by HW4 and is replaced with the HP22 Input Name Calculation X X Psychrometric calculation HP22 setting overrides HC2 probe setting Data refresh rate X When set...

Page 8: ...idity or dew frost point and the bottom line corresponds to temperature The display can be configured to show a trend indicator on each line increasing value decreasing value In the event of an alarm...

Page 9: ...irmware version Serial Nbr Serial number Address RS 485 address Name Device name User defined SensorTest Humidity sensor status Off Good SQ Tuned Bad Record On Off Data recording by the probe max 2000...

Page 10: ...dvice for measuring humidity The most common source of error when measuring relative humidity is a difference between the temperature of the probe and the temperature of the environment At a humidity...

Page 11: ...or to using this cable the ROTRONIC USB driver must be installed on the PC Both the driver and the installation instructions document E M HW4v2 Main are located on the HW4 CD As an alternative cable A...

Page 12: ...done prior to adjusting humidity o The calibration point is automatically deleted from the probe memory after an adjustment o Because the HP22 has no real time clock the date of the adjustment is not...

Page 13: ...roups Search for USB Masters After finding the HP22 with HW4 expand the device tree to see the HP22 functions Select Probe and Probe Adjustment For further instructions see HW4 manual E M HW4v2 A2 001...

Page 14: ...xing ratio by weight R Vapor concentration at saturation Dvs Vapor partial pressure E Vapor saturation pressure Ew Start up time and data refresh rate HP22 Start up time 3 s typical Data refresh rate...

Page 15: ...s the HW4 configuration software service cables calibration accessories and spare dust filters please see document E M HC2 accessories 9 Supporting documents Document File Name Contents E M HC2 Probes...

Page 16: ...6 Document title 2009 2010 Rotronic AG E M HP22 V1_21 E T HumiDefs Humidity Definitions Note All document file names have an extension corresponding to the document release number This extension is no...

Reviews: