59044E/2015-02
Subject to technical change without notice. Printing and other errors reserved.
ROTRONIC AG, Grindelstrasse 6, CH - 8303 Bassersdorf, Tel. +41 44 838 11 11, Fax +41 44
838 14 87
, www.rotronic.ch
ROTRONIC Instruments (UK) Ltd, Crompton Fields, Crompton Way, Crawley, West Sussex, RH10 9EE, UK, Phone +44 (0)1293 571000, Fax +44 (0)1293 571008, www.rotronic.co.uk
ROTRONIC Instrument Corp, 135 Engineers Road, Hauppauge, NY 11788, USA , Phone, +1 631 427-3898, Fax, +1 631 427-3902, www.rotronic-usa.com
ROTRONIC Instruments Pte. Ltd., 1003 Bukit Merah Central,
#
06-31 Inno Centre, Singapore 159836, Phone +65 6376 2107, Fax +65 6376 4439, www.rotronic.sg
Would you like more information?
You can fi nd a complete, up-to-date overview on the internet at
www.rotronic.com
.
TECHNICAL INFOR MATION.
COLD CHAIN TEMPERATURE LOGGER
Applications
Monitoring of the cold chain during transport of sensitive
freight such as pharmaceuticals, foods and technical pro-
ducts. The logger is designed for single use only.
TL-CC1
Type of logger
Single use
Parameter
Temperature
Temperature sensor
NTC thermistor
Accuracy
±0.5 °C (-30…70 °C)
Resolution
0.1 °C
Range of application
(temperature)
-30…70 °C / -22...158 °F
Range of application
(humidity)
< 80 %RH
Protection
IP65 (when placed in plastic bag)
Weight
Approx. 10 g
Battery
CR2032 (not replaceable)
Dimensions without bag
80(L) x 43(W) x 2.5(D) mm
Dimensions with bag
105(L) x 55(W) x 2.5(D) mm
Logging interval
0.5/5/10/30/60/90/120 min
Start delay
0.5/5/10/30/60/90/120 min
Alarm ranges
-20…-10 °C, -10…0 °C, 2…8 °C, 0…15 °C,
0…25 °C, 15…25 °, freely selectable values
Alarm type
Deactivated, single or cumulative
Storage period
12 months
Storage capacity
8192 data points
MARK function
Marking of up to 8 points during transport
Operation
START/STOP button, MARK button
LED indicators
LED “Low” fl ashes red
when value below alarm point
LED “Hi” fl ashes red
when value above alarm point
LED “OK” fl ashes green
during data logging
LED “Battery” fl ashes red
when low battery
Communication
USB 2.0 port, type A
Operating system
Windows
Conformity
GxP, EN 12830, FDA 21 CFR Part 11
and GAMP5
Delivery
In
box of 10
with instruction manual:
TL-CC1-10
Quick Guide
• Programing: plug into a USB port
• IP65: place into the sleeve and seal closed
• Start logging: press START key for 2 seconds
• Bookmarking: press MARK key
• Downloading of the PDF fi le: remove the logger
from the sleeve, plug into a USB port
PDF Report
Available from:
BSRIA Instrument Solutions
Tel No. 01344 459314
www.bis.fm