Operating Instructions
13
SG80AII Manual
www.rottlermfg.com
The accuracy of the seat angles depends on this.
While rotating the assembly tool Holder / carbide bit holder, the carbide tip’s cutting edge should just
touch the micrometer spindle, after the proper diameter has been achieve hand look the looking screws
and verify the diameter on the digital micrometer (BM)
Changing the Spindle Adapters
:
Once that you have the tool holder setup, fit the ball head tool holder into the spring free spindle adapter.
The SG80AII spindle has been engineered to allow ultra fast tooling changes.
Make sure the that spindle spring free locking nut is in the off lock position, line up the two ears of the
spindle adapter and insert into the spindle ISO 30 taper. The locking nut automatically will be on the lock
position, to remove turn the self-locking nut to the left position, hold the spindle adapter, it may drop on
the machine table. Damage will result.
Installing the Spherical self Aligning Toolholder
:
Once the spring free adapter is in the spindle, fit the Rottler Spherical Self aligning Toolholder
assembly
into the spindle adapter; make sure to align the locator pins before you fit it into the spindle adapter and
push it until you feel that is lock.
Summary of Contents for SG80AII
Page 2: ......
Page 12: ...Introduction Safety Installation 9 SG80AII Manual www rottlermfg com Electrical Enclosure ...
Page 49: ...Machine Parts 7 SG80AII Manual Type text www rottlermfg com Type text Base Assembly ...
Page 52: ...Machine Parts 10 SG80AII Manual Type text www rottlermfg com Type text Spindle Assembly ...
Page 56: ...Machine Parts 14 SG80AII Manual Type text www rottlermfg com Type text Transmission Assembly ...
Page 59: ...Machine Parts 17 SG80AII Manual Type text www rottlermfg com Type text Head Support Assembly ...