Troubleshooting 2 SG80AII
Manual
www.rottlermfg.com
4- Setting of the food pedal
operated system actuated
valve is misadjust
4- When the food pedal is not pressed, the clearance
between the left valve plunger (when looking from the
front of the machine) and the food pedal bracket should be
0.010” (0.20mm) whereas the clearance between the right
valve plunger and the food pedal bracket should be 0.039”
(0.75mm).
This can be achieve by loosing the two fixing screws and
the adjusting the valve mounting bracket.
Tighten back the bracket (see fig below).
When the food pedal is pressed, remove the black air tube
from the left port and it should be a full air flow, whereas
when you remove the green air tube from the right port it
should not be any air coming out.