Operator Controls
Rovema VPK Operators Manual
3/2000 VPK REV(B) PANELVIEW 600
5-28
SV Display
Mode Key
PV Display
Operator Interface
Temperature Controllers
The temperature controllers monitor and adjust the sealing
temperatures. There is one controller for each jaw assembly and one
for the seal band unit. The controller applies full voltage to the heating
cartridges until the set sealing temperature is reached. Then, it cuts
the power to the cartridges. While the temperature controller is on, it
toggles the power to the heating cartridges on and off to maintain the
sealing temperature.
Each controller includes a PV display, an SV display, a MODE key,
and two arrow keys. The PV display shows the current sealing
temperature. The SV display shows the desired sealing temperature.
The arrow keys are used to set the sealing temperature and the alarm
value.
Note:
When the sealing temperature is out of the range set by the
alarm value, the bagmaker stops bag forming and displays the
Out of Temperature alarm message.
Figure 5.25
Shows the temperature controllers.