Machine Setup Procedures
Rovema VPK Operators Manual
3/2000 VPK REV(B) PANELVIEW 600
6-10
Pneumatic Pressure Settings
The pressure settings for the engage/retract devices and the cooling
devices will depend on the production environment. Ambient
temperature, component wear, and other factors effect the pressure
settings for these devices. However, as a starting point, set the
pressure for the vertical seal engage/retract device, the belt
assemblies, and the horizontal cooling device to approximately 32
PSI. The vertical cooling device does not have a pressure gauge
because the pressure setting is important but not critical. When setting
the vertical cooling pressure, start by turning the flow control valve to
its medium position.
Figure 6.10
Shows the pneumatic pressure regulators.
Horizontal Cooling
Pressure
Belt Pressure
Vertical
Cooling
Vertical Sealing
Pressure