Replacing Heater Cartridges and Temp. Probes
This section describes how to replace the heating cartridges and the
temperature probes in the horizontal sealing jaws and in the vertical
sealing band unit.
Horizontal sealing Jaws
At some point, the heating cartridges and the temperature probes
inside of the horizontal sealing jaws must be replaced. Use the
following procedure to replace the heating cartridges and the
temperature probe in the front jaw assembly. The same procedure
can be applied to replace the heating cartridges and the temperature
probe in the rear jaw assembly. Before starting this procedure, make
sure that the bagmaker is locked-out and that the sealing jaws have
cooled.
Note:
It is not necessary to remove the c-frames from the machine to
perform this procedure. They have been removed in the
illustrations for clarity.
To replace the heater cartridges and the temperature probes:
1.
Push the knife extender inward to extend the cutting knife.
2.
Locate the knife securing screw under the front jaw body.
3.
Loosen the screw until the slotted knife can be removed from between
the jaws.
4.
Use a pair of pliers to remove the knife blade.
Figure 8.2
Shows the knife extender.
Knife
Extender
Hex Head
Bolt
Cap Screw