Replacing Heater Cartridges and Temp Probes
Horizontal sealing Jaws
9.
Remove the terminal housing from the jaw body.
10.
Remove the terminal housing cover to expose the ceramic
connectors.
11.
Disconnect the heating cartridges and the temperature probe from
the ceramic connectors.
12.
Remove the heating cartridges and the temperature probe from
the jaw body.
13.
Install the new heating cartridges and the new temperature probe
in the jaw body.
14.
Connect the heating cartridges and the temperature probe to the
ceramic connectors.
15.
Assemble and install the front jaw assembly into its c-frame.
Temperature
Probe
Ceramic
Connector
Heating
Cartridge
Terminal
Housing
Figure 8.4
Shows the terminal housing and the ceramic connectors.