Safety Instructions
Rovema VPK Operators Manual
3/2000 VPK REV(B) PANELVIEW 600
2-8
Lockout Procedures
Power Lockout Procedure
Use the following procedure to lockout the electrical power supply:
1.
Press the STOP push-button to halt the machine.
2.
Turn the MAIN DISCONNECT switch to the OFF position to disable
electrical power to the machine
3.
Pull out the lockout handle on the MAIN DISCONNECT switch.
4.
Place a lockout tag through the hole in the lockout handle.
5.
Place a pad lock through one of the holes in the lockout tag.
6.
Attempt to start the bagmaker by turning the MAIN DISCONNECT
switch to the ON position.
If the MAIN DISCONNECT switch will not turn to the ON position
then the lockout procedure was successful. If the switch will turn
to the ON position then the lockout procedure was not successful
and must be performed again.
Pad Lock
MAIN DISCONNECT Switch
Lockout Tag
Lockout Handle
Figure 2.8
Shows how to lockout the electrical supply to the bagmaker.