Parts and Functions
Rovema VPK Operators Manual
3/2000 VPK REV(B) PANELVIEW 600
3-39
Pneumatics System
Horizontal and Vertical Cooling Devices
The horizontal and vertical cooling devices release compressed air
onto the horizontal and vertical seals. These devices direct
compressed air from the primary manifold, through valves, through
air lines, to cooling wands. The valve for the horizontal cooling device
is a pressure regulator with a pressure gauge. The amount of horizontal
cooling is set using the regulators adjustment knob. The pressure
gauge allows for precise adjustments. The valve for the vertical sealing
device is a flow control valve. The amount of vertical cooling is set
using the valves adjustment knob.
Note:
There is no pressure gauge for the vertical cooling device
because the amount of air flow is not as critical as it is for the
horizontal cooling device.
Figure 3.38
Shows the horizontal and vertical cooling valves.
Horizontal
Cooling
Vertical
Cooling