Operator Controls
Rovema VPK Operators Manual
3/2000 VPK REV(B) PANELVIEW 600
5-13
Op. Interface > Settings Screen > Cam Settings
Knife Settings
These settings determine when the knife can be extended to cut a
bag from the film tube. When the encoder count is between these
settings, the motion controller will signal the PLC to energize the knife
solenoid valve. When the valve is energized, the knife will cut across
the film tube.
Figure 5.10.1
Shows the knife screen.
Film Tracking Settings
These settings determine when the PLC can make automatic film
tracking adjustments. When the encoder count is between these
settings, the motion controller will signal the PLC to move the film
carriage left or right to keep the edges of the vertical seal aligned.
Figure 5.10.2
Shows the auto film tracking screen.
KNIFE
###
ENABLED
F3
CAM OFF F5
###
CAM ON F4
SWITCH
AUTO FILM TRACKING
###
ENABLED
F6
CAM OFF F8
###
CAM ON F7
SWITCH