Operator Controls
Rovema VPK Operators Manual
3/2000 VPK REV(B) PANELVIEW 600
5-14
Op. Interface>Settings Screen>Cam Settings
Vibrator
These settings determine when the bag vibrator can be activated to
settle the product in the bag. When the encoder count is between
these settings, the motion controller will signal the PLC to energize
the vibrator solenoid valve and the vibrator will shake the bag. Typically
this occurs as the bag is being cut from the film tube.
Figure 5.11.1
Shows the vibrator screen.
Bag Folder
These settings determine when the bag folder can be extended to
fold the bottom seal against the bottom of the bag. When the encoder
count is between these settings, the motion controller will signal the
PLC to energize the bag folder solenoid valve and the folder will extend.
Just as the sealing jaws close, the edge of the folder should touch the
bottom seal and begin folding it.
Figure 5.11.2
Shows the bag folder screen
VIBRATOR
ENABLED
F3
SWITCH
###
###
CAM ON F4
CAM OFF F5
BAG DISCHARGE
ENABLED
F6
###
###
SWITCH
CAM ON F7
CAM OFF F8