ROWAN ELETTRONICA  S.R.L. - Via Ugo Foscolo, 20 - 36030 CALDOGNO (VICENZA)  ITALY

5

DESCRIPTION OF CONNECTION TERMINAL BOARD

1 - 6 -7

ZERO VOLT for input/output signals.

1 - 2

A.R. contact connection (static run consent) or NPN open collector transistor; when open, assents
acceleration ramp motor rotation up to maximum set speed and causes RUN led illumination. Closed, it
removes voltage from the motor and set acc./dec. ramp to zero.

1 - 3

torque limitation 0 / +10VDC signal input:
0VDC = minimum torque / +10VDC maximum torque

1 - 4

+10VDC 3mA reference voltage output for speed and torque (max. 3kohm load) regulation external
potentiometers.

1 - 5

speed regulation 0 / +10VDC signal input:
0VDC = zero turns / +10VDC = max speed

= extreme
3 = cursor

torque limitation external potentiometer connection

= extreme

(active with S1 open) R = 10kohm

4 = extreme
5 = cursor

speed regulation external potentiometer connection

6 = extreme

(active with S3 open) R = 10kohm

For connection of the 2 wire potentiometer (R = 10kohm) close microswitch S3 and use terminals 5 - 6only .

7 - 8

tachogenerator type 20VDC / 2800 rpm input

9 - 10

regulated output for powering starting and power windings of single phase Rowan motor (max 230VAC 8A
for code 119/92 up to 1HP and max 230VAC 15A for code 119/92/2 - 2HP).

11 - 12

power supply 230 VAC ±10% 50/60 Hz.  -  

 GROUND CONNECTION.

CIRCUIT SILKSCREEN -  TRIMMERS, MICRO-SWITCHES, LEDS

Summary of Contents for 119/92

Page 1: ...NUAL CODE119 92 REV 7 Date 15 10 18 EMC CONFORMITY FORASYNCHRONOUS ROWAN SINGLE PHASE MOTORS with TACHOMETER Motori azionamenti accessorieserviziperl automazione Via Ugo foscolo 20 CALDOGNO VICENZA IT...

Page 2: ...any inaccuracies contained in this manual due to printing and or transcription errors ROWAN ELETTRONICA s r l reserves the right to make any variations that it considers necessary for better function...

Page 3: ...ally through potentiometer or 0 10Vdc signal Input for pure contact or NPN open collector transistor for static run stop command 12Vdc 2mA Internal regulations through trimmer for acceleration deceler...

Page 4: ...ed system extremely silent Absence of typical PWM whistle and uniform from zero to the maximum motor rounds The application of controlled diodes on the power part gives reliability against extravoltag...

Page 5: ...3kohm load regulation external potentiometers 1 5 speed regulation 0 10VDC signal input 0VDC zero turns 10VDC max speed 1 extreme 3 cursor torque limitation external potentiometer connection 4 extreme...

Page 6: ...terorfrom0 10VDCsignalconnectedtoterminal3 closed activates board internal torque limitation from trimmer P1 S2 open cuts out torque limitation closed activatestorquelimitation S3 open in case of 3 wi...

Page 7: ...l it can be used for analog revolution counters display counters or other servomechanisms provided the overall loading being not lower than 5Kohm maxtachometercurrent 5mA Itisalwaysnecessary toavoidin...

Page 8: ...te it means that tachometer dynamo voltage is not reaching terminals 7 and 8 when this happens check the connections again Check attainment of maximum speed and if necessary fine adjust the maximum va...

Page 9: ...oswitch S1 and limit torque by regulating trimmer P1 Speed torque control from analog signal 0 10VDC In code 119 92 speed and torque regulations in addition to the conventional manual potentiometer ca...

Page 10: ...sets the ramp and switches off RUN led L2 If motor run stop were necessary with acceleration and deceleration ramps without immediately removing voltage from the motor in its stopping phase perform th...

Page 11: ...ve the screws attaching the brake to the hub 4 disconnect the brake cable from the terminal block 5 slide the brake off the hub At this stage the calibration can be made by adjusting the 3 bolts until...

Page 12: ...of motor windings with relative terminal board covering 9 FEET for B3 or B3 B5 versions 10 THERMICSENSORINSIDEWINDINGS 11 COMPENSATORRING 12 REAR RING for rear bearing housing 13 SERVICE TERMINAL BOA...

Page 13: ...r but according to an exponential curvewhichpresentsstrongvariationsatslowspeedandsmallvariationsathighspeed Ifonewishestoavoidthis behaviour and obtain a variation directly proportional to potentiome...

Page 14: ...of board C120 121 proceed as follows shift the wire connected to terminal NEG to terminal 1 of C119 92 shift the wire connected to terminal AR to terminal 2 of C119 92 exclude the wire connected to t...

Page 15: ...ROWAN ELETTRONICA S R L Via Ugo Foscolo 20 36030 CALDOGNO VICENZA ITALY BLOCK DIAGRAM...

Page 16: ...Foscolo 20 36030 CALDOGNO VICENZA ITALY EMC CONFORMITY Motori azionamenti accessorieserviziperl automazione Via Ugo foscolo 20 CALDOGNO VICENZA ITALY Tel 0039 444 905566 Fax 0039 444 905593 E mail inf...

Reviews: