facing the front because the
calibration
process
cannot
be
effected correctly otherwise.
Press
"Next“
afterwards. The calibration
process is started and will take some time.
Any remaining time is depicted.
Should the wizard detect soiling
and/or dust during the calibration
process, a message pops up. In this
case, check and clean the glass
plate. Afterwards, you can repeat
the process.
Please handle the calibration chart
with care. After calibration put it
back into the provided cardboard
box.
After completion of calibration, the scanner
is in working order and ready for use. For
this purpose, read chapter
"Simple Scan“
.
Figure 4.20: Calibration of scanner
In general, the Scan 850i software on the supplied CD-ROM is the most recent
version. However, it may also occur that a more recent version is already
available. The latter can now be downloaded and installed if you intend to do
so. Press the
Update
button in
ConfigManager
(see Chapter 8). For this
purpose, read Chapter 8.9.