User-defined
: If you select "
User-defined
“, you can enter any
dimension for the scan range in the displayed text fields:
Width
: Scan width in mm
Length
: Scan length in mm
Start at
: Start position in feeding direction from
beginning of document in mm
Zero point
: The zero point is marked in the middle of
the feed table of the scanner. In the default setting,
the middle of the document has to be close to the
zero point. By means of this option, you can shift the
reference point for the middle of the document to the
left (negative value) or right (positive value).
Figure 7.32: User-
defined format
7.10.3.4 Scaling/Margins
In the area "Scaling/Margins" you can
add, cut off, extend, or reduce margins
on the four sides of a document.
Enter positive values in the four text
fields in order to enlarge the left (1),
right (2), front (3) and/or rear margin
(4) (white). If you want to cut the
margin off, simply enter negative
values.
By means of the "Zoom" button, you
access a submenu where you can
select extensive scaling options.
Figure 7.33: Scaling/margin
Scale factor
: Enlargement
and/or reduction factor in %
(100 %: no scaling). Setting
range 1.0 to 999.0 %.
Page size
: Auto (according to
set factor) or scaled to a
special default format (e.g. ISO
A4).
Fixed format On/Off
: If the
fixed format is activated (
On
),
the length in feeding direction
is considered in addition to the
width when scaling to the
default format selected under
"Page size".
If the fixed format is enabled,
one part of the information is cut
off if the original is longer than
the fixed format to be scaled to
on the basis of the detected
width.
Orientation
: Selection of
portrait or landscape (when
Summary of Contents for Scan 850i