Overheating protection
A bimetal will trigger if the max. permissible operating temperature is exceeded. The appli-
ance switches back to a lower heating stage. It does not switch off completely in this case.
Anti-tipping device
If the appliance is knocked over while operating, the radiator will automatically switch off.
The appliance only functions in an upright position.
Thermal fuse
The thermal fuse trips in the event of an electrical overload (> 16 A) or a thermal overload (>
140 °C). The appliance switches off completely. The fuse is defective and must be replaced.
Contact the ROWI Service Centre for this (see Chapter 6).
1.5
Technical data
Model
HOR 1500/7/3 T Basic
HOR 2000/9/3 T Basic
Power connection
230 V~50 Hz
230 V~50 Hz
Max. heat output
1500 W
2000 W
Heating levels
3 (600/900/1500)
3 (800/1200/2000)
Heating ribs
7
9
Degree of protection
IP20
IP20
Protection class
I
I
Setup dimensions
34.0 x 23.5 x 63.5 cm
41.5 x 23.5 x 63.5 cm
Product weight
8.5 kg
11.2 kg
Tab. 1a: Technical data, Oil Radiator 1500/7/3 T Basic; 2000/9/3 T Basic
Model
HOR 2500/11/3 T Basic
HOR 2500/13/3 T Basic
Power connection
230 V~50 Hz
230 V~50 Hz
Max. heat output
2500 W
2500 W
Heating levels
3 (1000/1500/2500)
3 (1000/1500/2500)
Heating ribs
11 13
Degree of protection
IP20
IP20
Protection class
I
I
Setup dimensions
49.0 x 23.5 x 63.5 cm
56.5 x 23.5 x 63.5 cm
Product weight
12.9 kg
18.1 kg