3. Make sure that the C-Lok hooks are turned counterc-
lockwise (CCW) to the end-position first before you finally
lock the C-Loks.
4. For locking all C-Lok´s, please turn them clockwise into
end-position.
Note:
As soon as both dot indicators are in line, the C-Lok is
securely locked
Maximum Tensile and Torsion Load
Before setting up Cluster configurations, be aware of the maximum tensile and torsion load, listed
here below. Also make sure the mounting clamps are capable of supporting the total weight of your
configuration.
The different rigging options of all Cluster products result in different maximum tensile and torsion loads that must
not be exceeded for a safe overhead installation.
The maximum loads listed here below take into account the 10-fold safety!
1. Rigging by integrated 1/4 turn Camlocks on top- or rear side
User
Manual
Max. Tension Load: 90kg
Max. Torsion Load: 14.500 Nmm
Max. Tension Load: 90kg
Max. Torsion Load: 6.700 Nmm