39
User
Manual
User
Manual
Label:
ROXX CLUSTER B4 W
Model:
CLUSTER B4 W
Manufacturer:
ROXX
ID:
6A6Ah
Device ID:
201 xxxx
RDM functions
For easy identifying ROXX CLUSTER B4 W during RDM process the unit will strobe in white color.
PID
Function
Action
Values
0x00F0
DMX Start Adress
Set
001-512
0x00E0
DMX Personality
Set
7x DMX modes
0x00E1
DMX Slots
Read
n.a.
0x8001
Effect
Set
0= Stop Program / 1= Effect 1 / 2= Effect 2 / 3= Effect 3 / 4= Effect
4 / 5= Effect 5
0x8002
Effect Dimmer
Set
0x8003
Effect Speed
Set
0x8050
Master / Slave
Set
0= Master / 1= Slave
0x0500
Display Flip
Set
0= Off / 1= On
0x8051
Display Backlight
Set
0= Off / 1= On
0x8052
Display Lock
Set
0= Off / 1= On
0x8053
Startup Mode
Set
0= DMX / 1= AUTO / 2= Quick Light
0x8054
DMX Fail
Set
1= Hold / 2= Blackout / 3= Emergency
0x8055
Dimmer Curve
Set
1= Linear / 2= Exponential / 3= Logarithmic / 4= S-Curve
0x8056
Dimmer Response
Set
1= LED / 2= Medium / 3= Halogen
0x8057
Redshift
Set
0= Off / 1= On
0x8058
RAW Balance
Set
0= RAW / 1= User Calibrated
0x8024
User Calibration-White 1
Set
0x8023
User Calibration- Amber 1
Set
0x8020
User Calibration- Red 1
Set
0x8029
User Calibration- White 2
Set
0x8028
User Calibration- Amber 2
Set
0x8025
User Calibration- Red 2
Set
0x802E
User Calibration- White 3
Set
0x802D
User Calibration- Amber 3
Set
0x802A
User Calibration- Red 3
Set
7.5 RDM Templates*
The ROXX Show series features support for various RDM functions.
RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional com-
munication between the fixtures and the controller over a standard DMX line. This protocol will allow configuration,
status monitoring and management.
You will need a RDM controller to get control over the supported parameters. See the tables below for supported
RDM features.
*Note: During RDM identifying process CLUSTER B4 W flashes white alternately.