2A3/4
2-2-8
6. Feedshift section
• Jam in feedshift section (jam code 52)
The feedshift switch (FSSW) does not turn on within 1400 ms of the eject switch (ESW)
turning on.
ESW
1400 ms
On
Off
On
Off
FSSW
Timing chart 2-2-18
The feedshift switch (FSSW) does not turn off within 1400 ms of the eject switch (ESW)
turning off.
ESW
1400 ms
On
Off
On
Off
FSSW
Timing chart 2-2-19
7. Duplex section
• Jam in duplex stock section (jam code 60)
The switchback eject switch (SBESW) does not turn on within 856 ms of the duplex
forward solenoid (DUPFWDSOL) turning on.
DUPFWDSOL
856 ms
On
Off
On
Off
SBESW
Timing chart 2-2-20
Summary of Contents for Ri 4230
Page 3: ...SERVICE MANUAL Ri 4230 5230 ...
Page 13: ...4230 5230 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section ...
Page 14: ...1 1 5 2A3 4 CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1 ...
Page 100: ...4230 5230 S M MCA ELECTRICAL SECTION II II Electrical Section ...
Page 119: ......
Page 138: ......
Page 159: ...4230 5230 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION ...
Page 448: ...2A3 4 3 6 3 25 Toner scatters at the leading edge of the image See page 3 6 17 ...