2A3/4
3-3-96
( 4 ) Adjusting the DF magnification
Adjust magnification in the auxiliary scanning direction if magnification is incorrect when
the DF is used.
U053
(P.3-2-21)
U403
(P.3-3-40)
U402
(P.3-3-20)
U066
(P.3-3-39)
U070
U071
(P.3-3-98)
U404
(P.3-3-100)
U065
(P.3-3-37)
U034
(P.3-3-18)
Caution: Before making the following adjustment, ensure that the above adjustments
have been made in maintenance mode.
<Procedure>
Enter maintenance mode.
Place an original on the DF
and make a test copy.
Yes
No
Start
End
Exit maintenance mode.
Press the stop/clear key.
Is the image correct?
Enter "070" using
the numeric keys.
Press the interrupt key.
Setting range: –25 - +25
Changing the value by 1 changes
the magnification by 0.1%.
Reference: 0
Change the setting.
• For copy example 1, increase
the value using the Up key to
make the copy image longer.
• For copy example 2, decrease
the value using the Down keys
to make the copy image
shorter.
Press the print key.
Press the print key.
The new setting is stored.
Figure 3-3-114
Auxiliary
scanning
direction
Original
Main scanning
direction
Copy
example 1
Copy
example 2
Summary of Contents for Ri 4230
Page 3: ...SERVICE MANUAL Ri 4230 5230 ...
Page 13: ...4230 5230 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section ...
Page 14: ...1 1 5 2A3 4 CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1 ...
Page 100: ...4230 5230 S M MCA ELECTRICAL SECTION II II Electrical Section ...
Page 119: ......
Page 138: ......
Page 159: ...4230 5230 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION ...
Page 448: ...2A3 4 3 6 3 25 Toner scatters at the leading edge of the image See page 3 6 17 ...