2A3/4
3-6-15
(22) There is a regular
error between the
leading edges of the
original and copy
image when the
SRDF is used.
Causes
1. Misadjusted DF original scanning start position.
Check procedures/corrective measures
Readjust the DF original scanning start
position (see page 3-3-98).
Causes
1. Misadjusted DF original scanning
start position.
(21) There is a regular
error between the
centers of the original
and copy image when
the SRDF is used.
Causes
1. Misadjusted DF center line.
Check procedures/corrective measures
Readjust the DF center line (see page 3-3-97).
Causes
1. Misadjusted DF center line.