18” Inset Taper 010710
2.4.4.2 INSTALLING THE APPLIANCE (Checking the appliance setting pressure) 18 “ Inset
2.4.4.3 INSTALLING THE APPLIANCE (Checking the correct operation)
1. Remove the fret (Fig. 15), to gain access to the controls (Fig. 16).
2.
Press and turn the gas control anti-clockwise to the `IGN’ position. Keep the control fully depressed.
3.
Press and release the piezo button until the main burner behind the simulated fron coal has lit.
4.
Once lit, keep the gas control depressed for a further 20 seconds.
5.
Release the gas control and check that the main burner has remained alight.
6.
Press and turn the gas control anti-clockwise to the required setting. Replace the fret.
7.
To turn the appliance off, depress and turn the gas control to the `OFF’ position.
8.
In the event of the piezo button failing, the appliance may be lit by placing a lighted taper or match at the main burner
while depressing the gas control in the `IGN’ position.
IMPORTANT
After turning off or if the appliance goes out for any reason, wait three minutes before attempting to relight.
Page 10
The pressure test point enables verification of the inlet
pressure at the appliance under operating conditions and
can also be used to check the gas soundness of the
connections to the appliance gas controls (Fig. 14).
Restrictor elbow c/w PTP
(Pressure Test Point)
Piezo ignitor
Control knob
Rating label
Fig. 14
Gas Control
Piezo Button
Fret
Fig. 15