18” Inset Taper 010710
215mm
2.3 TECHNICAL
DATA
18” Inset
Fig.
7
Fig.
8
2.4
INSTALLING THE APPLIANCE (Ventilation)
Ventilation required for this appliance must be fitted with the rules in force and checked regularly for obstructions:-
If the appliance is installed in GREAT BRITAIN, additional ventilation is required.
If the appliance is installed in IRELAND, a minimal cross sectional area of 100cm
2
is required.
Page 7
Minimum
height of
opening is
555mm
Minimum
width of
opening is
415mm
Injector
044/341/196/087M
Gas Control
MP 21301B
Main Burner
Aeromatix AC03/211658
Thermocouple
T100/927-400
Ignition
Single spark electrode direct to main burner
Gas Connection
8mm OD (restrictor elbow)
Gas Type
G20 NATURAL GAS
Maximum Heat Input
7.8kW (26.003btu/hr) Gross
SPECIFICATIONS
Minimum Heat Input
3.6kW (12,283btu/hr)
Supply Setting Pressure
/- 1mbar (Cold)
Flue Types
Class 1
295mm
415mm
Minimum
Depth of
opening is
215mm