4
C603R 010909
Installation
The mains plug must be accessible after installation.
Ensure adequate space is maintained for the routing of the supply cord.
This appliance has three installation options: -
Option 2 Full Spacer
Offer the spacer frame (available as an option if not supplied) up to the wall ensuring
that the wider of the two internal faces is against the wall
(Fig. 2).
Ensure that the frame is square and true, mark and drill the wall using a
masonry bit and fix into position using screws (G) & the wall plugs (H) supplied.
Offer the appliance up to the frame and screw into position using the screws (K)
supplied.
Fig. 1
Option 1 Wall or Back Panel Fixing (Screw method)
For fitting the appliance into a blocked flue:
Offer the firebox into the opening.
Mark the holes provided, indicated by the four arrows (Fig. 1).
Drill, plug and screw the firebox to the wall or back panel.
Ensure a good seal is made between the firebox and wall or back panel.
Fixing hole
Fixing hole
Fixing hole
Fixing hole
Spacer fixing
holes
Fire fixing holes
Fig.2