background image

Installing the Appliance in Position

When the gas supply pipe has been laid to the position required, the surround should be fitted and sealed to
the chimney correctly. This is to prevent any seepage of flue products or to prevent any ingress of air into the
flue from anywhere other than the flue outlet of the fire. The easier method of installation is through the holes
provided in the front face of the vent box - this method will require drilling into the back panel of the
surround.  See Fig 8. Where it is undesirable to deface or damage the back panel, a cable fixing kit is provided
which can be fastened to the inner walls of the opening and the back of the box, see Fig 9. 

Before offering the vent box into the opening, the hearth should be protected from damage or scratches that
may occur during installation.

Locate and secure the firebox by the method chosen ensuring that a good seal exists with the back panel.  Lay
a gas supply to the location of the burner connecting elbow and place the burner into the vent box locate the
facia panel cut-out over the flange on the baseplate and secure into position with the 2 x No 8 self tap screws
supplied - complete the gas connection.

Note:   The complete installation should be tested for Gas soundness.

Fit the brass trim in position and remove the plastic coating from the brass finish.

Laying the Coal Bed

Fit the coal support shelf (ensuring that the front edge sits behind the three tabs) and the simulated coal front. 
Fig 10.

Referring to figures 10, 11, 12 and 13 lay the coals as follows: -

1.

Place 4 large round coals between the simulated coal front and the support shelf.  Fig 12

2.

Place 3 round coals between the gaps in the front row.  Fig 12

3.

Place the 5 small round coals between the gaps formed in the coals laid in 1 & 2 above. Fig 13

Checking Operation of Fire

Turn on the Gas supply at the meter and to the appliance at the isolating cock. Purge the air to the appliance.
Rotate the control knob to the ignition position, depress the control and push the piezo to ignite the pilot.
Check that the electrode is sparking between the tip of the thermocouple and continue until a pilot ignition is
established. Depress the control knob slightly and rotate anti-clockwise until the index symbol is aligned with
the small flame symbol on the indicator label.  Release and rotate the control knob to the high position (large
flame symbol) and check that the flame picture is satisfactory, then release the control knob - if the pilot does
not stay alight repeat until the pilot remains alight with the knob released.  Turn the gas control to the OFF
position, wait for 90 seconds, fully depress the gas control, turn to the ignition position and release the
control. Attempt to light the pilot with an already prepared match or taper, if the pilot lights the FSD is faulty.

Page 6

Summary of Contents for G31

Page 1: ...0102 095 50261 6 0 1 67 1 5 USERS INSTRUCTIONS THIS CAT I3P APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION ...

Page 2: ...petent person in accordance with the Gas Safety installation Use Regulations 1994 as amended or the rules in force and in accordance with the Manufacturers Installation Instructions Failure to comply could lead to prosecution The chimney or flue unless new must be swept before installation It is recommended that the appliance be serviced annually by a competent person and that the flue is checked ...

Page 3: ...t flame remains lit Refer to Fig 2 to view pilot Note For convenience the unit can be operated with the pilot only i e with the control knob set in the IGN position Push in the gas control slightly and turn anti clockwise so that the indicator dot is at the required setting Replace the fret controls cover To turn off the appliance and pilot turn the gas control clockwise from any position until th...

Page 4: ... 5 small round coals between the gaps formed in the coals laid in 1 2 above Fig 4 Cleaning the Front of the Appliance The fire must be turned off and allowed to cool The paintwork should be cleaned with a soft cloth or soapy water the brass trim has a clear lacquer coating to preserve the polished finish Spares and Service For spares and service contact your local supplier installer or direct to t...

Page 5: ...Page 4 Page 5 ...

Page 6: ...ddress __________________________________________________ __________________________________________________ Date of Purchase__________________________________________________ Serial Number __________________________________________________ Please return this section with any components that are faulty under guarantee MAXIMUM HEAT INPUT 6 kW 20470 Btu h Gross Royal Cozyfires are manufactured by CR...

Page 7: ...0102 095 50251 6 0 1 67 1 5 INSTALLATION and SERVICING INSTRUCTIONS THIS CAT I3P APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 8: ...an Oxy pilot sensor O D S that will cause the appliance to shut off in the event of continued spillage occurring under hazardous or blocked flue conditions The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required It is important when relaying the coal bed and coals to follow the instructions correctly This appliance is suitable for i...

Page 9: ...a minimum open area in the fret of 20 sq cms and 60 sq cms in the front Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e g many embossed vinyl wall coverings may become discoloured if located too close to the appliance Clearances required for combustible shelves are shown in fig 1 Care should be taken to ensure that when the appliance is installed ...

Page 10: ... incorrect flue terminals must not restrict any of the above flues The flue must only service a single appliance and not have any branches or traps that may impede the natural draught Any flue damper plate or restrictors shall be removed or fixed in the fully opened positions The front and base of the fire opening must be flat and square to ensure a good seal with the appliance this is to ensure t...

Page 11: ...d tube such as bundy suitable pieces of bundy are included in the fitting kit to assist the installer Where a concealed gas supply is used the installer is reminded of the requirements of BS 6891 1988 dealing with enclosed pipes The Standard requires that when a gas pipe is fed through a wall the pipe should be enclosed in a tight sleeve to protect against failure caused by movement and shall be c...

Page 12: ...coating from the brass finish Laying the Coal Bed Fit the coal support shelf ensuring that the front edge sits behind the three tabs and the simulated coal front Fig 10 Referring to figures 10 11 12 and 13 lay the coals as follows 1 Place 4 large round coals between the simulated coal front and the support shelf Fig 12 2 Place 3 round coals between the gaps in the front row Fig 12 3 Place the 5 sm...

Page 13: ...s will cause an initial odour which although not harmful may require additional ventilation until the odour has disappeared Any debris or soot is cleaned from the appliance Advise the customer that they should read their Users Instructions before operating the fire and always follow the advice in the section headed Removal of Debris or Soot Deposits The appliance must be serviced annually by a com...

Page 14: ... below the burner assembly it has to be removed from the vent box case by disconnecting the gas supply at the inlet elbow and unscrewing the two screws on the sides of the facia panel Where the supply is fed from the right hand side across the front of the fire it will be necessary to disconnect the supply from the isolation tap elbow i TO CLEAN OR REPLACE THE INJECTOR Remove the aeration sleeve r...

Page 15: ...Page 9 ...

Page 16: ...Page 10 ...

Page 17: ...Page 11 ...

Page 18: ......

Page 19: ...Page 12 ...

Page 20: ...Page 13 ...

Page 21: ...Page 14 No Figures 13 15 On this page ...

Page 22: ...omponents that fail under guarantee Maximum Heat Input 6 kW 20470 Btu h Gross Royal Cozyfires are manufactured by CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 5EX Spares Tel 01422 203963 Fax 01422 204475 Service GSA Ltd 01703 516611 Customer Service 01422 200660 Fax 01422 206304 Technical Help Line 0906 8633268 Calls charged at 50p per minute ...