MM79 010710
Page 9
2.4.4
INSTALLING THE APPLIANCE (Fitting the appliance in position)
Slimline Standard Mk2
BEFORE COMMENCING WORK, TURN OFF ALL APPLIANCES THAT ARE FED BY THE
METER.
ISOLATE THE GAS SUPPLY BY TURNING OFF AT THE METER.
It will be necessary to dismantle the burner unit from the firebox before installation into the opening. Remove the two fixing screws on
the left and right hand side of the burner. Lift and pull forward (Fig. 15).
2.4.4.1 INSTALLING THE APPLIANCE (Restrictor plate)
A restrictor plate is supplied with the IFU kit. This restrictor is for use when installing the appliance into a CLASS 1 FLUE ONLY! The
restrictor plate MUST NOT BE USED ON CLASS 2 AND PRE-CAST FLUES. The restrictor plate is fixed to the flue outlet using the
two screws provided in the IFU kit (Fig. 16).
Fixing Screw
Fig. 15
Fixing Screw
Restrictor plate – FOR USE ON
CLASS 1 FLUE ONLY!
Fix to the rear of the appliance using
the two screws provided in the IFU kit.
Fig. 16