MM79 010710
Page 6
2.3
TECHNICAL DATA
Slimline Standard Mk2
Fig. 7
Fig. 8
2.4
INSTALLING THE APPLIANCE (Ventilation)
Ventilation required for this appliance must be fitted with the rules in force and checked regularly for obstructions:-
If the appliance is installed in GREAT BRITAIN, additional ventilation is
NOT
normally required.
If the appliance is installed in IRELAND, a minimal cross sectional area of 100cm
2
is required.
600mm
505mm
Depth is
130mm w/out cable fixing
160mm with cable fixing
Minimum
height of
opening is
555mm
Minimum
width of
opening is
410mm
Forward projection is
50mm w/out front/fret
85mm with front/fret
Injector
044/341/196/120M
Gas Control
MP 21301A
Main Burner
Aeromatix AC03/211657
Thermocouple
T100/927-400
Ignition
Single spark electrode direct to main burner
Gas Connection
8mm OD (restrictor elbow)
Gas Type
G31 PROPANE GAS
Maximum Heat Input
5.5kW (18,766btu/hr) Gross
SPECIFICATIONS
Minimum Heat Input
3.6kW (12,283btu/hr)
Supply Setting Pressure
/- 1mbar (Cold)
Flue Types
Class 1, Class 2 & Pre-Cast