background image

4.

 

Depress the gas control slightly and turn clockwise until the indicator mark is opposite to the large flame
symbol. The burner will now run at its maximum rate.

5.

 

To turn the appliance ‘off’, return the control to the ‘off’ position.

6.

 

If for any reason the fire cuts out, return the control knob to the `off’ position and wait 3 minutes before re-
lighting.

5(029$/2)'(%5,6RU6227'(326,7

Allow the appliance to cool for two to three hours before removing all of the coals and ceramic blocks for
cleaning purposes. Once all the ceramics are removed from the fire bed check that no debris is located in the
burner slots (both front & rear).  If any debris is present it may easily be removed by using a small piece of thin
cardboard to ease out any foreign matter. Be sure to remove the cardboard after use.

 

Cleaning should be carried

out in a well-ventilated area or in the open air, by gently brushing with the pieces held away from your face so
that you avoid inhaling the dust. We do not recommend the use of a normal domestic vacuum cleaner, which
may blow dust back into the air.
.

6(77,1*837+(&2$/%('

 (See the identification sheet figure 13)

Components
2 burner inserts.

12 Large Coals.

Coal support shelves (L&R hand).

5 Medium Coals.                                 

Artificial coal front.                 

2 Triangular Coals

Place the left and right coal support shelves with the rebate on the underside, over the rear flange of the support
channel. Place the two shaped burner inserts into the channel between the front and rear ports of burner. Locate
the fibre artificial coal front on the shelf above the fascia panel. Figure 7.

&2$//$<287

First Layer. Position 4 large coals with their rear edge on the burner inserts. Place 3 large coals at the rear of the
coal support shelf and lay 2 further at the sides of the shelf. These coals are placed on their edge. 3 more large
coals are placed on the coal support shelf to complete the first layer. See figure 8.

Second Layer. Two triangular coals are placed one either side ensuring that they rest against the side and
straddle the gap between the front and second row large coal. Position the remaining 5 medium coals in the
positions shown in figure 9.

To obtain the best visual appearance it may be necessary to make slight adjustments to the position of the coals.

NOTE:    Additional coals must not be used

If any of the coals or the coal bed becomes damaged, lost or

broken, replacements must be obtained before the appliance is used.

9(17,/$7,21

Purpose built ventilation is not required for this appliance in GB only.  For Ireland (IE) ventilation is required
with a minimal cross sectional area of 100 sq. cms and should be checked regularly to ensure that it is free from
obstruction. It must be fitted in accordance with the rules in force.

&/($5$1&(726+(/9(6

Minimum clearances to underside of a 150mm (6ins) combustible shelf from the top of the fire opening must be
228mm (9ins).  Add 12.5mm (1/2in) to this clearance for every 25mm (1in) increased depth of shelf.

&/($5$1&(726,'(6

Minimum Clearance required to any combustible material to the side of the appliance must be 150mm (6in)

Page 3

Summary of Contents for Super Hot Toater

Page 1: ...SUPER HOT TOASTER USERS Pages 2 3 INSTALLATION Pages 4 7 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 2: ...ritish Standards Institution BS 5258 Part 12 1990 and is for use on Natural Gas only All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordance with the attached Installation Instructions failure to do so could lead to prosecution Areas of this appliance w...

Page 3: ...e channel between the front and rear ports of burner Locate the fibre artificial coal front on the shelf above the fascia panel Figure 7 2 287 First Layer Position 4 large coals with their rear edge on the burner inserts Place 3 large coals at the rear of the coal support shelf and lay 2 further at the sides of the shelf These coals are placed on their edge 3 more large coals are placed on the coa...

Page 4: ...The flue must be swept prior to installation unless new Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e g many embossed vinyl wall coverings may become discoloured if located too close to the appliance Clearances required for combustible shelves are shown on page 4 A hearth must always be provided to project forwards of the brass trim a minimum of...

Page 5: ... rigid or semi rigid tube to a pressure test elbow situated on the left hand side of the burner as shown in Fig 1 It advisable to provide a means of isolating the gas supply to the appliance for servicing with either a restrictor elbow or isolation cock as shown in Fig 1 A 45mm length of Bundy is supplied for use with a restrictor elbow or a 90 degree bend for use with an isolation cock the supply...

Page 6: ...ant reduction below an inlet pressure of 20mbar will indicate a restriction in the gas supply to the appliance that should be identified and corrected If there are any other appliances that are relatively high rated e g a central heating boiler fed from the same gas supply branch it is advisable to perform this observation with both appliances in operation 2 7 21 2 7 5 See figure 13 for identifica...

Page 7: ...ault and rectify the cause The test should be repeated if an extractor fan is situated in the room or in any connecting room with all the doors in that room opened 9 Remove the Fret and push the flame adjustment lever inwards replace the Fret and check that the flame picture changes to a longer softer flame Demonstrate the lighting and extinguishing procedures to the user 9 6 7 7 The curing effect...

Page 8: ...ont simulated coal To gain access to the components below the burner assembly it has to be removed from the Vent Box by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the fascia panel Where the supply is fed from the right hand side across the front of the appliance it will be necessary to disconnect the supply from the isolation tap or restrictor elbo...

Page 9: ...m the data badge located on the front controls panel Advantage should be taken of regular servicing and inspection for gas appliances to ensure their continued safe operation 6 257 3 576 67 Description Crosslee No GC No Piezo Igniter 40245 397 686 Control Knob 40232 Control Valve 41833 Oxy Pilot Burner Assembly 42313 170 415 Main Injector 41180 389 515 Coal Support 43010 Burner Inserts 42952 Front...

Page 10: ......

Page 11: ......

Page 12: ...No Fig 6 issued with this document ...

Page 13: ......

Page 14: ......

Page 15: ......

Reviews: