background image

),77,1*7+(9(17%2;

.

Position the box in the centre of the opening with a sufficient gap between the front flanges and the surround to
enable the tags on the rear of the brass trim to slide over. (Where a concealed gas supply is used feed the supply to
the position of the burner connection).  The box is secured in place with the two 10x11/4 round headed screws and
plastic plugs supplied in the fitting kit using the two holes in the base of box.  Replace the burner assembly in
position ensuring that the rear legs locate under the tags in the base plate and secure with the two screws provided.
Complete the gas connection to the burner as required and fit the brass trim by locating the tags in the cut outs in
the side flanges and sliding the trim down until the top tag locates over the top flange, remove the protective
plastic coating before lighting fire.

 

72&+(&.7+($33/,$1&(6(77,1*35(6685( /($.7(67

A Pressure Test Point at the inlet elbow enables verification of the inlet pressure of the appliance under operating
conditions and can also be used to check the gas soundness of the connections to the appliance gas control. To
check the joints of the burner assembly for gas soundness it will be necessary to carry out the examination prior to
installing into the case. If a manometer is used care must be taken to ensure that it is not disconnected with the gas
turned on and the fuel bed hot.

729(5,)<7+(,1/(735(6685(

The inlet pressure should be observed at /- 1mbar when the appliance is operating at its maximum rate.
Any significant reduction below an inlet pressure of 20mbar will indicate a restriction in the gas supply to the
appliance that should be identified and corrected. If there are any other appliances that are relatively high rated
(e.g. a central heating boiler) fed from the same gas supply branch, it is advisable to perform this observation with
both appliances in operation.

/2&$7,212)7+(),%5(%('

 (See figure 13 for identification of components)

Position the two burner inserts between the front and rear ports of the burner, and place the simulated coal front in
position as shown in figure 7. The L&R Hand coal support shelves are positioned so that the rebated channel on
the under side locate over the rear flange of the fibre support channel. Two stops prevent the shelf closing the gap
between the back of the burner inserts and the front edge of the shelf; there should be a minimum gap of 6mm.

&2$//$<287

First Layer. Position 4 large coals with their rear edge on the burner inserts. Place 3 large coals at the rear of the
coal support shelf and lay 2 further at the sides of the shelf. These coals are placed on their edge. 3 more large
coals are placed on the coal support shelf to complete the first layer. See figure 8.

Second Layer. Two triangular coals are placed one either side ensuring that they rest against the side and
straddle the gap between the front and second row large coal. Position the remaining 5 medium coals in the
positions shown in figure 9.

To obtain the best visual appearance it may be necessary to make slight adjustments to the position of the coals.

NOTE:    Additional coals must not be used

.

 

If any of the coals or the coal bed becomes damaged, lost or

broken, replacements must be obtained before the appliance is used

Page 6

Summary of Contents for Super Hot Toater

Page 1: ...SUPER HOT TOASTER USERS Pages 2 3 INSTALLATION Pages 4 7 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 2: ...ritish Standards Institution BS 5258 Part 12 1990 and is for use on Natural Gas only All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordance with the attached Installation Instructions failure to do so could lead to prosecution Areas of this appliance w...

Page 3: ...e channel between the front and rear ports of burner Locate the fibre artificial coal front on the shelf above the fascia panel Figure 7 2 287 First Layer Position 4 large coals with their rear edge on the burner inserts Place 3 large coals at the rear of the coal support shelf and lay 2 further at the sides of the shelf These coals are placed on their edge 3 more large coals are placed on the coa...

Page 4: ...The flue must be swept prior to installation unless new Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e g many embossed vinyl wall coverings may become discoloured if located too close to the appliance Clearances required for combustible shelves are shown on page 4 A hearth must always be provided to project forwards of the brass trim a minimum of...

Page 5: ... rigid or semi rigid tube to a pressure test elbow situated on the left hand side of the burner as shown in Fig 1 It advisable to provide a means of isolating the gas supply to the appliance for servicing with either a restrictor elbow or isolation cock as shown in Fig 1 A 45mm length of Bundy is supplied for use with a restrictor elbow or a 90 degree bend for use with an isolation cock the supply...

Page 6: ...ant reduction below an inlet pressure of 20mbar will indicate a restriction in the gas supply to the appliance that should be identified and corrected If there are any other appliances that are relatively high rated e g a central heating boiler fed from the same gas supply branch it is advisable to perform this observation with both appliances in operation 2 7 21 2 7 5 See figure 13 for identifica...

Page 7: ...ault and rectify the cause The test should be repeated if an extractor fan is situated in the room or in any connecting room with all the doors in that room opened 9 Remove the Fret and push the flame adjustment lever inwards replace the Fret and check that the flame picture changes to a longer softer flame Demonstrate the lighting and extinguishing procedures to the user 9 6 7 7 The curing effect...

Page 8: ...ont simulated coal To gain access to the components below the burner assembly it has to be removed from the Vent Box by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the fascia panel Where the supply is fed from the right hand side across the front of the appliance it will be necessary to disconnect the supply from the isolation tap or restrictor elbo...

Page 9: ...m the data badge located on the front controls panel Advantage should be taken of regular servicing and inspection for gas appliances to ensure their continued safe operation 6 257 3 576 67 Description Crosslee No GC No Piezo Igniter 40245 397 686 Control Knob 40232 Control Valve 41833 Oxy Pilot Burner Assembly 42313 170 415 Main Injector 41180 389 515 Coal Support 43010 Burner Inserts 42952 Front...

Page 10: ......

Page 11: ......

Page 12: ...No Fig 6 issued with this document ...

Page 13: ......

Page 14: ......

Page 15: ......

Reviews: