background image

0$,17(1$1&($1'6(59,&,1*

GENERAL

A.

 

REMOVAL OF DEBRIS OR SOOT DEPOSITS;

Allow the appliance to cool for one hour before removing all the coals and coal bed components for cleaning
purposes. Once all the components have been removed from the fire bed check that no debris has become lodged
in the burner ports (both front and rear). If any debris is present it may be easily removed with a thin piece of card
or similar to ease out any foreign matter. To ensure that the release of fibres from these RCF articles is kept to a
minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any
dust and soot accumulated in and around the fire before and after working on the fire. When replacing these
articles we recommend that the replaced items are not broken up, but are sealed within heavy duty polythene
bags, clearly labelled as RCF waste. This is not classified as "hazardous waste" and may be disposed of at a
tipping site licensed for the disposal of industrial waste. Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work
area and always wash your hands before eating or drinking. Any soot deposits may be removed from either the
Thermocouple or Electrode tips with a soft cloth, do not use abrasive materials.

B. SERVICING COMPONENTS BELOW THE BURNER ASSEMBLY
To remove trim, lift vertically to allow the formed tags in the rear of the trim to slide out of the notches in the
flanges of the box. (Assemble in the reverse sequence). Remove the coals, coal supports, burner inserts and front
simulated coal. To gain access to the components below the burner assembly it has to be removed from the Vent
Box by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the fascia
panel. Where the supply is fed from the right hand side across the front of the appliance it will be necessary to
disconnect the supply from the isolation tap or restrictor elbow. 

i) TO CLEAN OR REPLACE THE INJECTOR: Unscrew the compression nut connecting the gas supply to the
injector elbow while supporting the injector to prevent any distortion of the frame work. Unscrew and remove the
gas supply tube from the gas control valve, hold the injector lock nut with a spanner and rotate the injector.
Replace in the reverse order.                                                                        

ii) TO REPLACE THE GAS CONTROL / FSD: Disconnect the three gas pipes and the thermocouple from the
gas control. Pull the control knob from the spindle, unscrew the lock nut securing the front of the control valve
(niting plate assembly), and remove the gas control valve. Replace in the reverse order.

iii) TO REPLACE THE PIEZO IGNITER: Pull the igniter lead from the piezo igniter tab. Hold the piezo lock nut
and rotate the piezo to unscrew and remove. Replace in the reverse order.

iv) TO REPLACE THE OXY-PILOT ASSEMBLY: The assembly is not an item that can be serviced as part of its
calibration depends on the proximity of the spark electrode and thermocouple tip.  The assembly can be replaced
by removing the tube nut and the tube from the base of the pilot, the thermocouple from the FSD, the igniter lead
and the two M4 screws securing the bracket to the framework. Replace in reverse order, the spark gap is shown in
figure 12.

v) PROTECTIVE SIDE PLATES; These stainless steel plates are pushed over the flanges of the fibre retaining
channels and can be replaced if required.

Page 8

Summary of Contents for Super Hot Toater

Page 1: ...SUPER HOT TOASTER USERS Pages 2 3 INSTALLATION Pages 4 7 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 2: ...ritish Standards Institution BS 5258 Part 12 1990 and is for use on Natural Gas only All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordance with the attached Installation Instructions failure to do so could lead to prosecution Areas of this appliance w...

Page 3: ...e channel between the front and rear ports of burner Locate the fibre artificial coal front on the shelf above the fascia panel Figure 7 2 287 First Layer Position 4 large coals with their rear edge on the burner inserts Place 3 large coals at the rear of the coal support shelf and lay 2 further at the sides of the shelf These coals are placed on their edge 3 more large coals are placed on the coa...

Page 4: ...The flue must be swept prior to installation unless new Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e g many embossed vinyl wall coverings may become discoloured if located too close to the appliance Clearances required for combustible shelves are shown on page 4 A hearth must always be provided to project forwards of the brass trim a minimum of...

Page 5: ... rigid or semi rigid tube to a pressure test elbow situated on the left hand side of the burner as shown in Fig 1 It advisable to provide a means of isolating the gas supply to the appliance for servicing with either a restrictor elbow or isolation cock as shown in Fig 1 A 45mm length of Bundy is supplied for use with a restrictor elbow or a 90 degree bend for use with an isolation cock the supply...

Page 6: ...ant reduction below an inlet pressure of 20mbar will indicate a restriction in the gas supply to the appliance that should be identified and corrected If there are any other appliances that are relatively high rated e g a central heating boiler fed from the same gas supply branch it is advisable to perform this observation with both appliances in operation 2 7 21 2 7 5 See figure 13 for identifica...

Page 7: ...ault and rectify the cause The test should be repeated if an extractor fan is situated in the room or in any connecting room with all the doors in that room opened 9 Remove the Fret and push the flame adjustment lever inwards replace the Fret and check that the flame picture changes to a longer softer flame Demonstrate the lighting and extinguishing procedures to the user 9 6 7 7 The curing effect...

Page 8: ...ont simulated coal To gain access to the components below the burner assembly it has to be removed from the Vent Box by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the fascia panel Where the supply is fed from the right hand side across the front of the appliance it will be necessary to disconnect the supply from the isolation tap or restrictor elbo...

Page 9: ...m the data badge located on the front controls panel Advantage should be taken of regular servicing and inspection for gas appliances to ensure their continued safe operation 6 257 3 576 67 Description Crosslee No GC No Piezo Igniter 40245 397 686 Control Knob 40232 Control Valve 41833 Oxy Pilot Burner Assembly 42313 170 415 Main Injector 41180 389 515 Coal Support 43010 Burner Inserts 42952 Front...

Page 10: ......

Page 11: ......

Page 12: ...No Fig 6 issued with this document ...

Page 13: ......

Page 14: ......

Page 15: ......

Reviews: