background image

The Slimline Turbo is a decorative gas fire which incorporates a horizontal flue that has been designed specifically to be used in
applications that do not have a conventional chimney or flue but can be located so that the flue can terminate on an outside wall.

The fire is switched `ON’ and `OFF’ from a push button situated on the right hand top corner of the surround and is controlled by a
fully modulating thermoselector thermostat. Once the desired room temperature that has been selected by the control has been reached,
the gas input to the appliance is automatically reduced to low. The fire has been constructed to enable it to be installed into applications
where the warmth and comfort of an open fire and high radiant heat is required. This appliance is intended for decorative purposes, the
coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air to be entrained into the bed to ensure
clean combustion. An aerated single port steel burner is used running parallel across the front of the fire. A Flame Supervision Device
(FSD) is fitted to ensure that should the pilot flame be extinguished for any reason, (including turning off the appliance), the gas supply to
the burner is cut off until a full lighting sequence is repeated. A battery operated spark generator is used to ignite an Oxy/pilot sensor
(O.D.S) which will cause the appliance to 'shut off' in the event of continued spillage occurring under hazardous or blocked flue
conditions. The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required. It
is important when relaying the coal bed and coals to follow the instructions correctly.

TECHNICAL DATA

TYPE OF GAS

G20 only

SETTING PRESSURE

20 mbar +/- 1 mbar (cold)

GAS INPUTS (Gross)

Max 6.6 kW (22500 Btu/h)
Min 2.83 kW (9700 Btu/h)
Pilot 0.26 kW (890 Btu/h)

IMPORTANT NOTES

This appliance is intended for decorative purposes, it is designed and manufactured to the relevant requirements of EN 509, BSI S.I.T. 8
and BS 5258 Pt 16 : 1991, it is for use on Natural Gas Only.

Areas of this appliance will become hot after prolonged running and it is recommended that for the protection of the very young, elderly
and infirm a fireguard conforming to BS 6539 or BS 6778 be used.  Combustible materials should not be put or left on the hearth nor
should the coal bed be used to burn rubbish or other materials.

The type of front and fret recommended is shown as Fig 1 in this instruction, it has a perforated fret to allow air to be drawn into the coal
bed for combustion and over the controls for cooling purposes.  If other fronts and frets are to be used they must have a minimum open
area in the fret of 50 sq. cms and 60 sq. cms in the front.

Additional purpose built ventilation is not required for this appliance in GB only, for Ireland (IE) ventilation is required with a minimal
cross sectional area of 100 sq. cms and should be checked regularly to ensure that it is free from obstruction. It must be fitted in
accordance with the rules in force.

Care must be taken on the selection of wall coverings within close proximity of the fire as some vinyl and embossed materials may be
become discoloured by convected heat. Soft furnishings must be kept clear from the radiant heat of the fire and from impinging the
hearth area. The hearth must not be covered by any combustible materials such as carpets etc.

This appliance is fitted with an Oxy-pilot, which in the event of the flue being blocked or hazardous conditions exists which causes the
appliance to spill products of combustion, will shut `OFF' the gas supply.  If when the fire is relit the sequence is repeated the appliance
must be turned 'OFF' and not used until expert advice has been obtained.

In very strong wind conditions the fan may be heard to increase in speed, this is not detrimental to the operation of the appliance, as the
increase is to extract those products that may be prevented leaving the flue by the wind.  Exceptionally the fire may shut down and
require relighting due to a sustained strong gust.

The curing effect of heating the coals will cause an initial odour which, although not harmful, may require additional ventilation until the
odour has disappeared.

This product uses fuel effect pieces, gaskets and insulation material containing Refractory Ceramic Fibre (RCF), which are man-
made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract,
consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum.

This fire will run for 4.4 hours on one therm of gas with the gas control on the high setting.

-2-

Summary of Contents for U19023

Page 1: ...02 095 50281 SLIMLINE TURBO Flame System 5 USERS INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION ...

Page 2: ... or BS 6778 be used Combustible materials should not be put or left on the hearth nor should the coal bed be used to burn rubbish or other materials The type of front and fret recommended is shown as Fig 1 in this instruction it has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes If other fronts and frets are to be used they mu...

Page 3: ... the simulated coal front and remove the coal support shelf Once all the fibre components have been removed from the firebed check that no debris has fallen in or lodged the burner slots If any debris is present it may be easily removed by using a small piece of thin cardboard to ease out any foreign matter Be sure to remove the cardboard after use Any sooty deposits or debris left on the coals ma...

Page 4: ...antage should be taken of regular servicing and inspection of gas appliances to ensure their continued safe operation Short Parts List Description Crosslee Pt No Coal Support Shelves 42836 Front Simulated Coal 42769 Fibre Back 42830 Set of Coals 42658 9 volt Battery PP3S REGISTRATION RECORD Purchaser s Name and Address Supplier s Name and Address Date of Purchase Serial No Please return these deta...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: